Standard" Configuration Mode; Top-Up Times" Configuration Mode - Cornelius UFB1 Installation And Service Manual

Dispensing valve
Hide thumbs Also See for UFB1:
Table of Contents

Advertisement

7.1.1

"Standard" configuration mode

The module stores the fill times configured for each beverage size. During configuration, the "PGM" indicator lights up. The last
configured fill time is stored when exiting configuration mode.
NOTICE!
Use the actual beverage sizes and amounts of ice for the configuration.
1. Call up "Standard" configuration mode by pressing the program button (Fig. 46/2) for 5 sec-
onds.
The "PGM" indicator (Fig. 46/4) lights up.
2. Place a cup on the drip tray of the base unit and under the dispensing nozzle of the dispensing
valve.
3. Press the button (Fig. 46/1) for the beverage size to be configured until the fill level in the cup
is reached.
The "PGM" indicator (Fig. 46/4) lights up.
The fill time is stored in the module when you exit configuration mode.
4. Repeat the process for all beverage sizes.
5. Exit configuration mode by pressing the program button (Fig. 46/2) or the "Start & Stop" button (Fig. 46/3) for 5 seconds.
The "PGM" indicator (Fig. 46/4) goes out.
The last fill time set for each beverage size is stored.
7.1.2

"Top-up times" configuration mode

The module stores two fill times with a timed pause that is configured for each beverage size. During configuration, the "PGM"
indicator flashes. The last two configured fill times are stored when exiting configuration mode.
NOTICE!
Use the actual beverage sizes and amounts of ice for the configuration.
1. Call up the "Top-up times" configuration mode by pressing the program button (Fig. 47/3) and
the "S" button (Fig. 47/1) or the "S" (Fig. 47/1) and "XL" buttons (Fig. 47/2) simultaneously for
5 seconds.
To prevent any unintentional dispensing, press the program button (Fig. 47/3) slightly earlier
than the "S" button (Fig. 47/1).
The "PGM" indicator (Fig. 47/5) flashes.
2. Place a cup on the drip tray of the base unit and under the dispensing nozzle of the dispensing
valve.
3. Press the button (Fig. 47/1) for the beverage size to be configured until the fill level in the cup
is reached.
The "PGM" indicator (Fig. 47/5) flashes.
4. Wait until the foam has settled in the cup and press the button (Fig. 47/1) for the beverage size again until the fill level in the
cup is reached.
The fill time, pause and top-up time are stored in the module when you exit configuration mode.
5. Repeat the process for all beverage sizes.
6. Exit configuration mode by pressing the program button (Fig. 47/3) or the "Start & Stop" button (Fig. 47/4) for 5 seconds.
The "PGM" indicator (Fig. 47/5) goes out.
The last fill time, pause and top-up time set for each beverage size is stored.
Cornelius Deutschland GmbH
Document no. TD2004100
Version 15/03/2019, Index 0
Configuring and adjusting
1
PGM
WAIT
4
3
Fig. 46
1
PGM
WAIT
5
4
Fig. 47
Installation and service manual Dispensing valve
2
2
3