5.2

Carrying out a visual inspection of the seals on the diffusor and baffle

1. Unlock the outlet nozzle by turning it.
2. Pull the outlet nozzle with the baffle downwards out of the dispensing valve.
3. Remove the baffle (Fig. 16/1) from the outlet nozzle (Fig. 16/2).
4. Check the seal (Fig. 17/1) of the baffle (Fig. 17/4) for damage and elasticity.
Replace any damaged seals.
5. Check the seal (Fig. 17/2) of the diffusor (Fig. 17/3) for damage and elasticity.
Replace any damaged seals.
6. Insert the baffle (Fig. 18/1) into the outlet nozzle (Fig. 18/2).
NOTICE!
The outlet nozzle is easier to insert into the dispensing valve if it is moistened with water beforehand.
Cornelius Deutschland GmbH
Document no. TD2004100
Version 15/03/2019, Index 0
Maintenance
Fig. 15
Fig. 16 Standard dispens-
ing nozzle
Fig. 17 Standard dispens-
ing nozzle
Fig. 18 Standard dispens-
ing nozzle