3. Pull the control panel forwards out of the dispensing valve.
4. Slide the new control panel into the dispensing valve.
5. Connect the electrical cables (Fig. 24/2) for the control panel (Fig. 24/3) on the pull-type sole-
noid (Fig. 24/4).
6. Connect the plug (Fig. 24/1) of the control panel (Fig. 24/3).
Finishing tasks
1. Mount the rear valve cover, see chapter 6.2.
6.4
Replacing the OptiFill module
Prerequisites
The rear valve cover has been removed.
Spare parts
UFB1 OptiFill: Module
1. Disconnect the plug (Fig. 27/1) of the OptiFill module (Fig. 27/5).
2. Disconnect the electrical cables (Fig. 27/2) for the OptiFill module (Fig. 27/5) on the pull-type
solenoid (Fig. 27/6).
3. Disconnect the electrical cables (Fig. 27/3) for the OptiFill module (Fig. 27/5) on the micros-
witch.
4. Disconnect the electrical cable (Fig. 27/4) for the OptiFill module (Fig. 27/5).
5. Carefully pull the electrical cables (Fig. 28/1) for the OptiFill module (Fig. 27/5) out of the dis-
pensing valve.
6. Disconnect the electrical cable (Fig. 28/2) for the OptiFill module (Fig. 27/5).
7. Pull the OptiFill module forwards out of the dispensing valve.