Maximal Series Features; Acm8Cb Access Power Controller Modules; Eflow Power Supply/Charger - Altronix Maximal3FD Installation Manual

Access power controllers with power supplies
Hide thumbs Also See for Maximal3FD:
Table of Contents

Advertisement

ACM8CB Access Power Controller Modules:

• Sixteen (16) independently trigger controlled outputs. Output options:
a) Sixteen (16) Fail-Safe filtered power outputs.
b) Sixteen (16) Fail-Secure filtered power outputs.
c) Any combination of the above.
• Sixteen (16) Access Control System trigger inputs. Input trigger options:
a) Sixteen (16) normally open (NO) dry trigger inputs.
b) Sixteen (16) open collector inputs.
c) Any combination of the above.
• Sixteen (16) unswitched filtered aux. power outputs (outputs are rated @ 2.5A).
• Red LEDs on ACM8CB board indicate individual outputs are triggered (relays energized).
• Fire Alarm disconnect (latching or non-latching) is individually selectable for any or all of the
sixteen (16) outputs.
Fire Alarm disconnect input trigger options:
a) Normally open (NO) or normally closed (NC) dry trigger input.
b) Polarity reversal input from FACP signaling circuit.
• Green LED on ACM8CB board indicates FACP disconnect is triggered.
• FACP output relay indicates that FACP input is triggered
(form "C" contact rated @ 1A/28VDC not evaluated by UL).
• eFlow Power Supply/Charger board provides common power for both ACM8CB Access Power Controller
boards (factory wiring) and all connected access control devices (field wiring).
• ACM8CB board main fuses are rated @ 10A. Output PTCs are rated @ 2.5A.

eFlow Power Supply/Charger:

• Input: 120VAC, 60Hz.
• For output voltage and supply current refer to MaximalFD series Configuration Chart, pg. 3.
• Auxiliary Power-Limited output rated @ 1A (unswitched).
• Overvoltage protection.
• Built-in charger for sealed lead acid or gel type batteries.
• Maximum charge current 1.54A.
• Automatic switch over to stand-by battery when AC fails. Transfer to stand-by battery power is instantaneous
with no interruption.
• Supervised Fire Alarm disconnect (latching or non-latching) 10K EOL resistor. Operates on a normally open
(NO) or normally closed (NC) trigger.
• AC fail supervision (form "C" contacts).
• Battery fail & presence supervision (form "C" contacts).
• Low power shutdown. Shuts down DC output terminals if battery voltage drops below 71-73% for 12V units
and 70-75% for 24V units (depending on the power supply). Prevents deep battery discharge.
• For fuse ratings refer to MaximalFD series Configuration Chart, pg. 3.
• Green AC Power LED indicates 120VAC present.
• AC input and DC output LED indicators.
• Short circuit and overload protection.
• Enclosure accommodates up to four (4) 12VDC/12AH batteries.
Enclosure dimensions (H x W x D): 26" x 19" x 6.25" (660.4mm x 482.6mm x 158.8mm).
- 4 -
MaximalFD Series Features: