Access Power Controllers with
Power Supplies
Installation Guide
Models Include:
Maximal3F
- 12VDC @ 4.6A or 24VDC @ 5.2A.
- Sixteen (16) fuse protected non power-limited outputs.
Maximal5F
- 12VDC @ 8.6A.
- Sixteen (16) fuse protected non power-limited outputs.
Maximal7F
- 24VDC @ 9.2A.
- Sixteen (16) fuse protected non power-limited outputs.
Rev. MSFF052419
Installing Company: ________________ Service Rep. Name: ______________________________________
Address: ___________________________________________________ Phone #: _____________________
Altronix Corp.
140 58th St. Brooklyn, NY
More than just power.
TM

Advertisement

Table of Contents
loading

Summary of Contents for Altronix Maximal3F

  • Page 1 Access Power Controllers with Power Supplies Installation Guide Models Include: Maximal3F - 12VDC @ 4.6A or 24VDC @ 5.2A. - Sixteen (16) fuse protected non power-limited outputs. Maximal5F - 12VDC @ 8.6A. - Sixteen (16) fuse protected non power-limited outputs.
  • Page 2: Table Of Contents

    Enclosure Dimensions ............pg. 15 - 2 - Maximal3F/Maximal5F/Maximal7F Access Power Controllers (Fused)
  • Page 3: Maximalf Series Overview

    CSA C22.2 No.205 - Signal Equipment. ULC-S319-05 Electronic Access Control Systems will be invalidated through the use of any add-on, expansion, memory or other module manufactured by the manufacturer or other manufacturers. Maximal3F/Maximal5F/Maximal7F Access Power Controllers (Fused) - 3 -...
  • Page 4: Maximal Series Features

    • Short circuit and overload protection. • Enclosure accommodates up to four (4) 12VDC/12AH batteries. Enclosure dimensions (H x W x D): 26” x 19” x 6.25” (660.4mm x 482.6mm x 158.8mm). - 4 - Maximal3F/Maximal5F/Maximal7F Access Power Controllers (Fused)
  • Page 5: Maximalf Installation Instructions

    There are no user serviceable parts inside. Refer installation and servicing to qualified service personnel. 3. Select desired DC output voltage by setting SW1 to the appropriate position on the Maximal3F power supply (Fig. 1a, pg. 9). Maximal5F power supply is factory set at 12VDC and Maximal7F power supply is factory set at 24VDC.
  • Page 6: Maintenance

    14. Installation of Tamper Switch (Fig. 3b, pg. 10): Mount UL Listed tamper switch (Altronix model TS112 or equivalent) at the top of the enclosure. Slide the tamper switch bracket onto the edge of the enclosure approximately 2” from the right side (Fig. 3b, pg. 10).
  • Page 7: Power Supply Board Led Diagnostics

    A removed battery is reported within 5 minutes. Battery reconnection is reported within 1 minute (Class 2 power-limited) (Fig. 3, pg. 10). Stand-by battery connections. + BAT – Maximum charge current 1.54A (non power-limited) (Fig. 3, pg. 10). Maximal3F/Maximal5F/Maximal7F Access Power Controllers (Fused) - 7 -...
  • Page 8: Access Power Controller Terminal Identification

    From normally open and/or open collector sink trigger inputs INPUT 8 IN, GND (request to exit buttons, exit PIRs, etc.) 12VDC to 24VDC trigger controlled outputs are rated at 2.5A. Maximal3F: 10.0-13.2VDC @ 4.6A or 20.19-26.4VDC @ 5.2A. Maximal5F: 10.03-13.2VDC @ 8.6A. Maximal7F: 20.17-26.4VDC @ 9.2A. OUTPUT 1- OUTPUT 8 Fail-Safe [NC positive (+) &...
  • Page 9: Power Supply Board Output Voltage Settings

    MAG. Electromagnetic LOCK Door Holders Intact = One P/S Input Intact = DC Input Cut = Dual P/S Input Cut = AC Input J2 J1 NC C NO COM OUTPUT 8 Maximal3F/Maximal5F/Maximal7F Access Power Controllers (Fused) - 9 -...
  • Page 10: Maximalf Battery Hookup And Tamper Switch Installation

    Fig. 3 Maximal3F, Maximal5F, and Maximal7F. Tamper Switch Wire Strap (from Enclosure to Door) Power Supply Board AC FAIL BAT FAIL AC DELAY SHUTDOWN 5A 250V 1 min. enable TRIGGER EOL NC C NO NC C NO + AUX –...
  • Page 11: Nec Power-Limited Wiring Requirements

    (non power- limited) Battery Connections (non power-limited) Fig. 4a Incorrect Wire Correct Wire Handling Handling External Supervisory Jacketed Connections Shield (power-limited) Wire Insulation Pull back Solid Copper external jacketed Conductors shield approx. 1/2”. Maximal3F/Maximal5F/Maximal7F Access Power Controllers (Fused) - 11 -...
  • Page 12: Facp/Optional Power Supply Hook-Up Diagrams

    Fig. 9 Normally Closed: Latching FACP trigger trigger input: input with reset (This output has not been evaluated by UL): N.C. RESET N.C. DRY SWITCH TRIGGER INPUT N.C. JUMPER TRIGGER JUMPER INPUT - 12 - Maximal3F/Maximal5F/Maximal7F Access Power Controllers (Fused)
  • Page 13 Notes: Maximal3F/Maximal5F/Maximal7F Access Power Controllers (Fused) - 13 -...
  • Page 14 Notes: - 14 - Maximal3F/Maximal5F/Maximal7F Access Power Controllers (Fused)
  • Page 15: Enclosure Dimensions

    19” (482.6mm) Altronix is not responsible for any typographical errors. 140 58th Street, Brooklyn, New York 11220 USA | phone: 718-567-8181 | fax: 718-567-9056 website: www.altronix.com | e-mail: info@altronix.com | Lifetime Warranty | Made in U.S.A. MEMBER IIMaximal3F/5F/7F Series E24S...
  • Page 16 - UL Listed in the U.S. and Canada. - Local or remote control of up to (2) two Altronix eFlow power output(s) via LAN and/or WAN. - Monitor real time diagnostics: DC output voltage, output current, AC & battery status/service, input trigger state change, output state change and unit temperature.