Altronix Maximal3V Installation Manual
Altronix Maximal3V Installation Manual

Altronix Maximal3V Installation Manual

Access power controllers

Advertisement

Quick Links

Access Power Controllers
Installation Guide
Models Include:
Maximal3V
- 12VDC @ 5A or 24VDC @ 5.4A.
- Sixteen (16) fuse protected outputs.
Maximal5V
- 12VDC @ 9A.
- Sixteen (16) fuse protected outputs.
Maximal7V
- 24VDC @ 9.4A.
- Sixteen (16) fuse protected outputs.
Rev. SF022607
More than just power.
TM

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Maximal3V and is the answer not in the manual?

Questions and answers

Summary of Contents for Altronix Maximal3V

  • Page 1 Access Power Controllers Installation Guide Models Include: Maximal3V - 12VDC @ 5A or 24VDC @ 5.4A. - Sixteen (16) fuse protected outputs. Maximal5V - 12VDC @ 9A. - Sixteen (16) fuse protected outputs. Maximal7V - 24VDC @ 9.4A. - Sixteen (16) fuse protected outputs.
  • Page 2: Table Of Contents

    Access Power Controller Typical Application Diagram (for each ACM8) . . . . . . . . . . . . . . . . pg. 7 Maximal3V and MaximalV5 Battery Hookup and Tamper Switch Installation . . . . . . . . . . . pg. 8 Maximal7V Battery Hookup and Tamper Switch Installation .
  • Page 3: Maximal V Series Overview

    Maximal V Series Overview: Altronix Maximal Access Power/Controllers distribute and switch power to access control systems and acces- sories . They convert a 220VAC (working range 198VAC - 256VAC), 50/60Hz input into sixteen (16) indepen- dently controlled 12VDC or 24VDC fuse protected outputs . These Fail-Safe/Fail-Secure power outputs may be converted to dry form “C”...
  • Page 4: Maximal V Installation Instructions

    There are no user serviceable parts inside. Refer installation and servicing to qualified service personnel. 3 . Select desired DC output voltage by setting SW1 to the appropriate position on the Maximal3V power supply, (Figs. 1 and 1a, pg. 7). Maximal5V power supply is factory set at 12VDC and Maximal7V power supply is factory set at 24VDC .
  • Page 5: Maintenance

    No DC output . Short circuit or thermal overload condition . No DC output . Loss of AC . Discharged battery . Red (Bat) Battery Status Normal operating condition . Battery fail/low battery . Maximal3V / Maximal5V / Maximal7V Access Power Controllers (Fused) - 5 -...
  • Page 6: Access Power Controller Led Diagnostics

    L, G, N Connect 220VAC 50/60Hz to these terminals: L to hot, N to neutral . Maximal3V - 12VDC @ 5A or 24VDC @ 5 .4A to ACM8 boards . + DC – Maximal5V - 12VDC @ 9A to ACM8 boards .
  • Page 7: Power Supply Board Output Voltage Settings

    Door Holders Intact = One P/S Input Intact = DC Input Cut = Dual P/S Input Cut = AC Input J2 J1 NC C NO COM OUTPUT 8 Maximal3V / Maximal5V / Maximal7V Access Power Controllers (Fused) - 7 -...
  • Page 8: Maximal3V And Maximalv5 Battery Hookup And Tamper Switch Installation

    **24VDC operation: Connect two (2) 12VDC batteries in series Fig. 3b Honeywell Model 112 Tamper Switch Enclosure or equivalent Edge of (Not Included) Enclosure to Access Control Panel or U.L. Listed Reporting Device - 8 - Maximal3V / Maximal5V / Maximal7V Access Power Controllers (Fused)
  • Page 9: Maximal7V Battery Hookup And Tamper Switch Installation

    **24VDC operation: Connect two (2) 12VDC batteries in series Fig. 4a Honeywell Model 112 Tamper Switch Enclosure or equivalent Edge of (Not Included) Enclosure to Access Control Panel or U.L. Listed Reporting Device Maximal3V / Maximal5V / Maximal7V Access Power Controllers (Fused) - 9 -...
  • Page 10: Nec Power-Limited Wiring Requirements For Maximal3V

    Battery Connections (non power-limited) Fig. 5a Incorrect Wire Correct Wire Handling Handling External Jacketed Shield Wire Insulation Pull back Solid Copper external jacketed Conductors shield approx. 1/2”. - 10 - Maximal3V / Maximal5V / Maximal7V Access Power Controllers (Fused)
  • Page 11: Nec Power-Limited Wiring Requirements For Maximal5V

    Battery Connections (non power-limited) Fig. 6a Incorrect Wire Correct Wire Handling Handling External Jacketed Shield Wire Insulation Pull back Solid Copper external jacketed Conductors shield approx. 1/2”. Maximal3V / Maximal5V / Maximal7V Access Power Controllers (Fused) - 11 -...
  • Page 12: Nec Power-Limited Wiring Requirements For Maximal7V

    Fig. 7a Incorrect Wire Correct Wire Handling Handling External Jacketed Shield Battery Connections (non power-limited) Wire Insulation Pull back Solid Copper external jacketed Conductors shield approx. 1/2”. - 12 - Maximal3V / Maximal5V / Maximal7V Access Power Controllers (Fused)
  • Page 13: Facp Hook-Up Diagrams

    Fig. 9 Normally Open - Non-Latching FACP trigger input: N.O. TRIGGER INPUT Fig. 10 Normally Open FACP Latching trigger input with reset: N.O. TRIGGER INPUT N.C. RESET SWITCH JUMPER Maximal3V / Maximal5V / Maximal7V Access Power Controllers (Fused) - 13 -...
  • Page 14: Facp Hook-Up Diagrams

    Fig. 11 Normally Closed - Non-Latching FACP trigger input: N.C. DRY TRIGGER INPUT JUMPER Fig. 12 Normally Closed - Latching FACP trigger input with reset: N.C. RESET SWITCH N.C. TRIGGER JUMPER INPUT - 14 - Maximal3V / Maximal5V / Maximal7V Access Power Controllers (Fused)
  • Page 15 Notes: Maximal3V / Maximal5V / Maximal7V Access Power Controllers (Fused) - 15 -...
  • Page 16: Enclosure Dimensions