Altronix Maximal11FDV Installation Manual
Altronix Maximal11FDV Installation Manual

Altronix Maximal11FDV Installation Manual

Access power controllers with power supplies

Advertisement

Quick Links

Access Power Controllers with
Power Supplies
Installation Guide
Models Include:
Maximal11FDV
- Power Supply 1:
12VDC @ 3.3A or 24VDC @ 3.6A.
- Power Supply 2:
12VDC @ 3.3A or 24VDC @ 3.6A.
- Sixteen (16) PTC protected outputs.
Maximal33FDV
- Power Supply 1:
12VDC @ 5.3A or 24VDC @ 5.6A.
- Power Supply 2:
12VDC @ 5.3A or 24VDC @ 5.6A.
- Sixteen (16) PTC protected outputs.
Rev. DFDV031115
Installing Company: ________________ Service Rep. Name: ______________________________________
Address: ___________________________________________________ Phone #: _____________________
Maximal55FDV
- Power Supply 1: 12VDC @ 9.3A.
- Power Supply 2: 12VDC @ 9.3A.
- Sixteen (16) PTC protected outputs.
Maximal77FDV
- Power Supply 1: 24VDC @ 9.6A.
- Power Supply 2: 24VDC @ 9.6A.
- Sixteen (16) PTC protected outputs.
Maximal75FDV
- Power Supply 1: 12VDC @ 9.3A.
- Power Supply 2: 24VDC @ 9.6A.
- Sixteen (16) PTC protected outputs.
More than just power.
TM

Advertisement

Table of Contents
loading

Summary of Contents for Altronix Maximal11FDV

  • Page 1 Access Power Controllers with Power Supplies Installation Guide Models Include: Maximal11FDV Maximal55FDV - Power Supply 1: - Power Supply 1: 12VDC @ 9.3A. 12VDC @ 3.3A or 24VDC @ 3.6A. - Power Supply 2: 12VDC @ 9.3A. - Power Supply 2: - Sixteen (16) PTC protected outputs.
  • Page 2: Table Of Contents

    Enclosure Dimensions ............pg. 15 - 2 - Maximal11FDV / Maximal33FDV / Maximal55FDV / Maximal77FDV / Maximal75FDV Access Power Controllers (PTC)
  • Page 3: Maximalfdv Series Overview

    9.6A – – – – 26.4 26.4 26.4 26.4 All units: These unit are suitable to power: sensors, electro-mechanical devices (e.g. electric door strikes). Maximal11FDV / Maximal33FDV / Maximal55FDV / Maximal77FDV / Maximal75FDV Access Power Controllers (PTC) - 3 -...
  • Page 4: Maximal Series Features

    • Enclosure accommodates up to four (4) 12VDC/12AH batteries. Enclosure dimensions (H x W x D): 26” x 19” x 6.25” (660.4mm x 482.6mm x 158.8mm). - 4 - Maximal11FDV / Maximal33FDV / Maximal55FDV / Maximal77FDV / Maximal75FDV Access Power Controllers (PTC)
  • Page 5: Maximalfdv Installation Instructions

    3. Select desired DC output voltage by setting SW1 to the appropriate position on the power supply board on Maximal11FDV and Maximal33FDV, (Fig. 1, pg. 9). Maximal55FDV power supply is factory set at 12VDC. Maximal77FDV power supply is factory set at 24VDC. Maximal75FDV consists of one (1) power supply board that is factory set at 12VDC, and one (1) power supply board that is factory set at 24VDC.
  • Page 6: Maintenance

    Note: Maximum charge current is 1.54A. Expected battery life is 5 years; however, it is recommended to change batteries within 4 years or less if necessary. - 6 - Maximal11FDV / Maximal33FDV / Maximal55FDV / Maximal77FDV / Maximal75FDV Access Power Controllers (PTC)
  • Page 7: Power Supply Board Led Diagnostics

    Battery reconnection is reported within 1 minute (Fig. 3, pg. 10). + BAT – Stand-by battery connections. Maximum charge current 1.54A (Fig. 3, pg. 10). Maximal11FDV / Maximal33FDV / Maximal55FDV / Maximal77FDV / Maximal75FDV Access Power Controllers (PTC) - 7 -...
  • Page 8: Access Power Controller Terminal Identification

    IN, GND 12VDC to 24VDC trigger controlled outputs. Maximum load per output is 2.5A. Maximal11FDV: P/S 1 - 9.8-13.2VDC @ 3.3A P/S 2 - 9.8-13.2VDC @ 3.3A or P/S 1 - 19.9-26.4VDC @ 3.6A P/S 2 - 19.9-26.4VDC @ 3.6A or P/S 1 - 9.8-13.2VDC @ 3.3A and P/S 2 - 19.9-26.4VDC @ 3.6A.
  • Page 9: Power Supply Board Output Voltage Settings

    Intact = One P/S Input Intact = DC Input Cut = Dual P/S Input Cut = AC Input J2 J1 NC C NO COM OUTPUT 8 Maximal11FDV / Maximal33FDV / Maximal55FDV / Maximal77FDV / Maximal75FDV Access Power Controllers (PTC) - 9 -...
  • Page 10: Maximalfdv Battery Hookup And Tamper Switch Installation

    Honeywell Model 112 Tamper Switch Fig. 3a Enclosure or equivalent Edge of (Not Included) Enclosure to Access Control Panel or U.L. Listed Reporting Device - 10 - Maximal11FDV / Maximal33FDV / Maximal55FDV / Maximal77FDV / Maximal75FDV Access Power Controllers (PTC)
  • Page 11: Nec Power-Limited Wiring Requirements

    Incorrect Wire Correct Wire Handling Handling External Jacketed Supervisory Shield Connections (power- limited) Wire Insulation Pull back Solid Copper external jacketed Conductors shield approx. 1/2”. Maximal11FDV / Maximal33FDV / Maximal55FDV / Maximal77FDV / Maximal75FDV Access Power Controllers (PTC) - 11 -...
  • Page 12: Facp/Optional Power Supply Hook-Up Diagrams

    (This output has not been evaluated by UL): N.C. RESET N.C. DRY SWITCH TRIGGER INPUT N.C. JUMPER TRIGGER JUMPER INPUT - 12 - Maximal11FDV / Maximal33FDV / Maximal55FDV / Maximal77FDV / Maximal75FDV Access Power Controllers (PTC)
  • Page 13 Notes: Maximal11FDV / Maximal33FDV / Maximal55FDV / Maximal77FDV / Maximal75FDV Access Power Controllers (PTC) - 13 -...
  • Page 14 Notes: - 14 - Maximal11FDV / Maximal33FDV / Maximal55FDV / Maximal77FDV / Maximal75FDV Access Power Controllers (PTC)
  • Page 15: Enclosure Dimensions

    140 58th Street, Brooklyn, New York 11220 USA | phone: 718-567-8181 | fax: 718-567-9056 website: www.altronix.com | e-mail: info@altronix.com | Lifetime Warranty | Made in U.S.A. MEMBER IIMaximal11FDV/33FDV/55FDV/75FDV/77FDV Series G31R Maximal11FDV / Maximal33FDV / Maximal55FDV / Maximal77FDV / Maximal75FDV Access Power Controllers (PTC) - 15 -...
  • Page 16 - UL Listed in the U.S. and Canada. - Local or remote control of up to (2) two Altronix eFlow power output(s) via LAN and/or WAN. - Monitor real time diagnostics: DC output voltage, output current, AC & battery status/service, input trigger state change, output state change and unit temperature.

Table of Contents