5.2 Approvals Available - Ametek Drexelbrook IntelliPoint RF RNL Series Installation And Operating Instructions Manual

Point level switch
Table of Contents

Advertisement

Section 5: Specifications (Continued)

5.2 Approvals Available:

FM / FMc
Explosionproof for Class I, Division 1, Groups A, B, C and D; Dust-
Ignition proof for Class II, III, Division 1, Groups E, F and G; Non-
incendive for Class I, Division 2, Groups A, B, C & D; Suitable for Class
II, III, Division 2, Groups F & G hazardous outdoor Type 4, 4X, IP66
(classified) locations with Intrinsically Safe connections to Class I, II, III,
Division 1, Groups A, B, C, D, E, F and G hazardous (classified) locations
in accordance with Control Drawing 420-0004-144-CD.
ATEX (FM14ATEX0049X)
Integral or Remote Sensor
Temperature Class Process Temps (Integral Sensor)
IECEX (FTZU 18.0007X)
Ex db ia [ia Ga] IIC T5 Gb/Ga
System
Ex tb ia [ia Da] IIIC T90ºC Db/Da
-30ºC ≤ Ta ≤ 58ºC
Ex ia IIC T5 Ga
Sensor
Ex ia IIIC T90ºC Da
-30ºC ≤ Ta ≤ 58ºC
Reference control drawing 420-0004-563-CD for entity and installation requirements
Special Condition for Safe Use
1. THE EQUIPMENT SHALL NOT BE APPLIED IN AN EXPLOSIVE DUST ATMOSPHERE WHERE HIGH
ELECTROSTATIC CHARGING PROCESSES ARE PRESENT THAT COULD RESULT IN PROPAGATING BRUSH
DISCHARGES.
2. CONSULT THE MANUFACTURER IF DIMENSIONAL INFORMATION ON THE FLAMEPROOF JOINTS IS
NECESSARY.
3. AMBIENT TEMPERATURE RANGE:
-30°C TO +58°C FOR RXLX/SXRXTX INTELLIPOINT RF LEVEL SYSTEM
-30°C TO +70°C FOR RXTX/SXRXTX INTELLIPOINT RF TWO-WIRE POINT LEVEL SYSTEM
II 2 (1) G Ex d [ia] IIC T5... T2 -30
II 2 (1) D Ex tb [ia] IIIC T90°C -30
T5
T4
T3
T2
C < TAMB < +70
O
C < TAMB < +70
O
100°C
135°C
200°C
230°C
33
Specifications
C; IP66
O
C; IP66
O
2460