Configuring The Management Interface For Remote Access - Lenovo RackSwitch G8332 Installation Manual

Lenovo network operating system
Hide thumbs Also See for RackSwitch G8332:
Table of Contents

Advertisement

Configuring the Management Interface for Remote Access

1. Log onto the switch using the serial console port or management port on the G8332 
2. Enter management interface mode.
3. Configure an IP address, subnet mask, and VLAN assignment.
84
G8332 Installation Guide
To manage the switch remotely using Telnet, SNMP, or a web‐browser, you must 
first configure the management interface. You can use DHCP to automatically 
configure the interface (enabled by default), or you can manually configure the 
following IP parameters:
IP address and subnet mask 
Gateway address
By default, DHCP is enabled on the management interface. If there is no DHCP 
offer received, the switch uses the default management IP address 
(192.168.50.50/24). This address is overwritten when a DHCP address is 
received for that interface. If DHCP is enabled and there is no static address 
configured for DHCP, requests will continue to be sent. This feature does not 
change existing DHCP functionality.
To configure the management interface for remote management, complete the 
following steps.
front panel.
for Lenovo Enterprise Network Operating System (ENOS):  
G8332> enable
G8332# configure terminal
G8332(config)# interface ip 128
G8332(config­ip­if)#
for Lenovo Cloud Network Operating System (CNOS):  
G8332> enable
G8332# configure device
G8332(config)# interface mgmt 0
G8332(config­if)#
for Lenovo Enterprise Network Operating System (ENOS):  
G8332(config­ip­if)# ip address 10.254.87.6
G8332(config­ip­if)# ip netmask 255.255.255.0
G8332(config­ip­if)# vlan 1
G8332(config­ip­if)# no shutdown
G8332(config­ip­if)# exit
G8332(config)#