Removing and Replacing a Power Supply Module
Removing the Power Supply Module
Statement 5
© Copyright Lenovo 2017
The rear panel of the G8332 has two bays for hot‐swap power supply modules.
Two active power supply modules are required for load‐sharing and redundancy.
If one power supply module fails, you can replace it without powering off the
switch or disrupting switch functions.
For proper airflow when operating the switch with only one power supply
module, the empty power supply bay must be closed by a blank power filler plate.
CAUTION:
The power control button on the device and the power switch on the power
supply do not turn off the electrical current supplied to the device. The device
also might have more than one power cord. To remove all electrical current from
the device, ensure that all power cords are disconnected from the power source.
Chapter 4: Removing and Replacing Components
61