3. From the front, slide the switch into the rack at the desired height.
4. Secure the switch unit to the rack posts with M6 screws (Item 3), washers (Item 6), 
5.
6.
7.
8.
40
G8332 Installation Guide
and either clip nuts (Item 4) or cage nuts (Item 5). Torque the screws to 
approximately 5.7 Nm ± 0.1 Nm (50 inch‐pounds).    
3
6
If installing the 1U air‐duct option, see the instruction on page
Connect all external cables in accordance with the "Cabling Guidelines" on 
page
37.
Initialize the switch. See Chapter 5, "Initializing the G8332", on page
If the switch is a replacement unit, set Vital Product Data (see "Configuring Vital 
Product Data" on page
4
76).
48.
79.