Configuring The Management Interface For Remote Access - Lenovo RackSwitch G8296 Installation Manual

Hide thumbs Also See for RackSwitch G8296:
Table of Contents

Advertisement

Configuring the Management Interface for Remote Access

1. Log onto the switch using the serial console port or management port on the G8296
2. Enter management interface mode.
3. Configure an IP address, subnet mask, and VLAN assignment.
92
G8296 Installation Guide
To manage the switch remotely using Telnet, SNMP, or a web-browser, you must
first configure the management interface. You can use DHCP to automatically
configure the interface (enabled by default), or you can manually configure the
following IP parameters:
IP address and subnet mask
Gateway address
By default, DHCP is enabled on the management interface. If there is no DHCP
offer received, the switch uses the default management IP address
(192.168.50.50/24). This address is overwritten when a DHCP address is
received for that interface. If DHCP is enabled and there is no static address
configured for DHCP, requests will continue to be sent. This feature does not
change existing DHCP functionality.
To configure the management interface for remote management, complete the
following steps.
front panel.
for Lenovo Enterprise Network Operating System (ENOS):
G8296> enable
G8296# configure terminal
G8296(config)# interface ip 128
G8296(config-ip-if)#
for Lenovo Cloud Network Operating System (CNOS):
G8296> enable
G8296# configure device
G8296(config)# interface mgmt 0
G8296(config-if)#
for Lenovo Enterprise Network Operating System (ENOS):
G8296(config-ip-if)# ip address 10.254.87.6
G8296(config-ip-if)# ip netmask 255.255.255.0
G8296(config-ip-if)# vlan 1
G8296(config-ip-if)# no shutdown
G8296(config-ip-if)# exit
G8296(config)#