Batch Settings - Iced Tea / Coffee Version; Temperature Settings; Diagnostics - Fetco Extractor TBS-21A User Manual

Iced tea brewer iced tea / coffee brewer
Hide thumbs Also See for Extractor TBS-21A:
Table of Contents

Advertisement

Batch Settings – Iced Tea / Coffee Version
(See previous page for Iced Tea Only version)
Parameter
Name
0.0
Software Version
1.0
Batch Volume
1.1
Extract %
1.2
Pulses
1.3
Brew Time
(If 1.2 > 1)
1.4
Dilution During
Brew
(If 1.2 > 1)
1.5
Dilution Delay
(If 1.4 = 0)
1.6
Drip Delay
2.0
Brew Volume
2.2
Pulses
2.3
Brew Time
(If 2.2 > 1)
2.6
Drip Delay

Temperature Settings

Parameter
Name
3.0
Water Temp. (°F)
4.0
Brew Only at Set
Temperature
5.0
Enter Diagnostics
Press SET to continue.

Diagnostics

Address
Description
50
Water Level
in Tank
51
Tank Temperature
52
Brew Switch, top
(Full batch or iced tea)
53
Brew Switch, bottom
(Half batch or coffee)
54
Brew Basket Sensor
55
Dispenser Sensor
56
Display Recent Errors
57
Master Clear Errors
58
Reset Defaults
59
Dispenser Sensor
(Choice not available on
Iced Tea / Coffee version)
60
Enter Relay Test
Press SET to continue.
Range
1.0 – 3.2 gal.
1% - 50%
1 – 25
2:00 – 15:00
minutes
0 - 1
0 – 15:00 min.
0:10 – 15:00 min.
0.1 – 1.0 gal.
1 – 25
2:00 – 15:00
minutes
0:10 – 15:00 min.
Range
Increment
180°F - 211°F
1°F
0 - 1
0 - 1
Range
Default
0 - 1
32°F -
212°F
0 - 1
0 - 1
0 - 1
0 - 1
0 - 1
0
0 - 1
0
0 - 1
1
0 - 1
0
Increment
Default Setting
0.1
3.0 gal.
1%
25%
1
1
10 sec.
4:00 min.
0
0:10
3:00 min.
10 sec.
3:00 min.
0.1
0.8 gal.
1
8
10 sec.
4:00 min.
10 sec.
1:00 min.
Default Setting
Comment
205°F
1
0=Will brew only at set
temperature.
1=Will brew at any
temperature.
0
0 = no
1 = yes
Comment
Tests if water is touching probe.
0 = Tank is less than full
1 = Tank is full
Displays current tank temperature.
Press switch to test. Display should toggle
between 0 and 1.
Press switch to test. Display should toggle
between 0 and 1.
To test, slide the brew basket in and out. Display
should toggle between 0 and 1.
0 = Brew basket out. 1 = Brew Basket in.
Press switch to test. Display should toggle
between 0 and 1.
Scroll to display the 5 most recent errors.
Clears errors stored in memory. (See #56)
Clears error code 050 and 051.
Changes all settings to default factory settings.
0 = Do not reload defaults
1 = Reload all default settings
0=Will brew with or without dispenser in place.
1=Will brew only if dispenser is in place.
0 = no
1 = yes
8
Comment
Not to exceed 1 gal.
0 = no
1 = yes

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents