Batch Settings

Turn the brewer off by pressing the main power switch.
Press the main power switch again to turn the unit on.
The last 2 digits of the model number will display briefly, then S t b.
Quickly hold the STOP button for 3 seconds.
The display will show the software version. Example:
Press STOP to continue.
Batches are numbered 1 – 2 (CBS-2041e) or 1 – 4 (CBS-2042e)
Next, the first batch parameter is displayed – batch 1, brew volume
Use the SCROLL UP and SCROLL DOWN buttons to adjust.
Press the STOP button to go to the next parameter – brew time.
Continue this way until all parameters are programmed for batch #1.
(See the chart below for an explanation of each parameter.)
Next, batch #2 programming begins.
Batches 2 and 4 may be disabled by leaving them set to "OFF".
Change to "ON" to enable. Batches 1 and 3 cannot be disabled.
After all batches are programmed, go to temperature settings.
Important! After programming, you must press the HOT WATER button to save the settings and exit
programming mode, or changes will be lost. You may exit programming at any time.
Batch Parameters
X=Batch Number (1 - 4)
Parameter
Name
X.0
Batch Enabled or
Disabled
X.1
Brew Volume
(Gallons)
X.2
Brew Time (Min:Sec)
X.3
Bypass Percent
X.4
Prewet Percent
X.5
Prewet Delay
(Min:Sec)
X.6
Drip Delay (Min:Sec)

Programming

BATCH #
1.1 1.00
Example: Left Side – Large Batch – Volume 1.0 Gal.
Range
On/Off
0.25 – 1.25
2:00 – 24:00
0.00 – 40.0%
0.00 – 15.0%
0:10 – 5:00
0:30 – 6:00
Minutes
PARAMETER
SETTING
(See next page)
Increment
Default Setting
Batch 1 & 3 = ON
Batch 2 & 4 = OFF
0.01
1.0 gallons
0:30
4:00 minutes
1%
0 %
1%
0 %
0:10
1:00 minute
0:10
1:30 minute
9
Display
42
S t b
P r G
MAIN POWER
0.0 3.2
SWITCH IS
BEHIND
FRONT LEG.
1.1 1.00
1.2 4.00
2.0 OFF
7
200
Comment
Batch 1 & 3 cannot
be disabled.
To display liters, see
# 59 in Advanced
Settings section.
Percentage of total
brew volume
Percentage of total
brew volume
The time between
prewetting and start
of brew cycle.
The time between
end of brew cycle
and unlocking of
brew basket.

Hide quick links: