Fetco EXTRACTOR V+ CBS-1150 User’s Manual & Operator Instructions

Fetco EXTRACTOR V+ CBS-1150 User’s Manual & Operator Instructions

Hide thumbs Also See for EXTRACTOR V+ CBS-1150:

Advertisement

FETCO COFFEE BREWER: CBS-1150 EXTRACTOR

TABLE OF CONTENTS

Specifications and Requirements ................................ 2
Rough-In Drawings ...................................................... 2
Electrical and Output Specifications ............................ 3
Starting The Brew ........................................................ 4
Enter Programming ...................................................... 4
Exit Programming & Save ............................................ 4
PROGRAMMING MENU LAYOUT . ............................ 5
A PROGRAM ............................................................... 6
B GENERAL................................................................. 7
C INPUTS .................................................................... 8
D OUTPUTS ................................................................ 8
E OTHER ..................................................................... 8
F SAVE & EXIT ............................................................ 9
CONTACT INFORMATION
FETCO®
FOOD EQUIPMENT TECHNOLOGIES COMPANY
600 ROSE ROAD
LAKE ZURICH • IL • 60047-0429 • USA
INTERNET: www.fetco.com
©2017 FOOD EQUIPMENT TECHNOLOGIES COMPANY
USER'S GUIDE &OPERATOR INSTRUCTIONS
 
 
 
 
 
 
 
 
 
 
 
 
 
CBS-1152-XV+
Error Codes .................................................................. 9
Operator Training ....................................................... 10
Cleaning & Maintenance ............................................ 10
Installation Guide........................................................ 11
Parts Diagrams CBS-1151V+ .................................... 14
Parts Diagrams CBS-1152V+ .................................... 16
CBS-1151V+ Tank Assembly..................................... 18
CBS-1152V+ Tank Assembly..................................... 19
Wiring diagrams ......................................................... 20
PHONE: (800) 338-2699 (US & CANADA)
(847) 719-3000
FAX: (847) 719-3001
EMAIL: sales@fetco.com
techsupport@fetco.com
PATENTS: WWW.fetco.com/patents
P167
REV:000
V+
®
 
 
 
 
 
 
 
 
NOVEMBER 2017

Advertisement

Table of Contents
loading

Summary of Contents for Fetco EXTRACTOR V+ CBS-1150

  • Page 1: Table Of Contents

    USER’S GUIDE &OPERATOR INSTRUCTIONS FETCO COFFEE BREWER: CBS-1150 EXTRACTOR ® ™ CBS-1151-XV+ CBS-1152-XV+ TABLE OF CONTENTS Specifications and Requirements ........ 2 Error Codes ..............9     Rough-In Drawings ............2 Operator Training ............10     Electrical and Output Specifications ......3 Cleaning &...
  • Page 2: Cbs-1151-Xv

    Field conversion is to be made only by licensed electrician. Disconnect equipment from power supply before service. Remove jumper between L2 and L3, and apply power to L3 Go to fetco.com for the latest versions of all information P167 November 2017...
  • Page 3: Electrical And Output Specifications

    3 X 3.0 kW 230/400 Hardwired 12.4 22.5 gal/85 liters 3L,N,PE (CE) E115262 3 X 5.0 kW 230/400 3L,N,PE Hardwired 14.1 20.4 38.3 gal/145 liters Go to fetco.com for the latest versions of all information P167 November 2017 Page 3...
  • Page 4: Starting The Brew

    EXIT (“F”) toggle to the EXIT- toggle to the SAVE toggle to the SAVE- SAVE your changes screen appears YES screen screen YES screen and EXIT Go to fetco.com for the latest versions of all information P167 November 2017 Page 4...
  • Page 5: Programming Menu Layout

    (A1&A4 are permanent) screen remaining (3 or 6) A70 programming “A” menus. Make keys. See SAVE & any changes as EXIT in previous required table Go to fetco.com for the latest versions of all information P167 November 2017 Page 5...
  • Page 6: A Program

    A20 that a button BATCH A2 BATCH A5 position can be made active or inactive. Position A1 does not display this step BATCH A3 BATCH A6 Go to fetco.com for the latest versions of all information P167 November 2017 Page 6...
  • Page 7: B General

    Use the formula above to determine the correct setting Set lower to increase volume, higher to decrease volume. See “PROGRAM” B5 and B6 For valve settings and calibration. Factory set brew valve flow rates are in liter/min Go to fetco.com for the latest versions of all information P167 November 2017...
  • Page 8: C Inputs

    Load From USB Will need reboot drive device. Demonstrates the controls for training. DEMO Mode DEMO ON/OFF Will need reboot Disables all components in demo mode Go to fetco.com for the latest versions of all information P167 November 2017 Page 8...
  • Page 9: F Save & Exit

    Brew basket must be in place Insert brew basket into brewer rails to BSKT enable brewer This is a Insert Brew Basket SAFETY FEATURE Go to fetco.com for the latest versions of all information P167 November 2017 Page 9...
  • Page 10: Operator Training

    5. Do not attempt to move hot beverage equipment once it is filled. Drain equipment before moving. 6. FETCO commercial coffee brewers prepare large amounts of coffee or tea in a single batch using very hot water 7. Commercial coffee brewers provides very hot water from the sprayhead, brew basket and faucet when it is pulled.
  • Page 11: Installation Guide

    4. Damages resulting from improper installation are not covered by the warranty, and will void the warranty. Electrical: 1. All FETCO brewers require an electrical ground wire. Installation without grounding is dangerous. 2. Note Equipotentiality Terminal, if present, (To identify the terminals which, when connected together, bring the various parts of equipment or of a system to the same potential, not necessarily being the earth (ground) potential, e.g.
  • Page 12 Do not operate if unit has been submerged or saturated with water. Labels and warnings for hot beverage equipment For BACK PANEL of equipment (1046.00035.00) Go to fetco.com for the latest versions of all information P167 November 2017 Page 12...
  • Page 13 1102.00064.00 HANDLE W/MAGNET ASSEMBLY, BLACK Optional colored 1102.00065.00 HANDLE W/MAGNET ASSEMBLY, RED handle Optional colored 1102.00066.00 HANDLE W/MAGNET ASSEMBLY, GREEN handle Optional colored 1102.00067.00 HANDLE W/MAGNET ASSEMBLY, ORANGE handle Go to fetco.com for the latest versions of all information P167 November 2017 Page 13...
  • Page 14: Parts Diagrams Cbs-1151V

    1086.00031.00 E115162 1104.00096.01 1401.00159.00 1086.00031.00 E115180 1104.00095.01 1401.00152.00 1086.00008.00 E115190 1104.00097.01 1401.00153.00 1086.00008.00 E115191 1104.00095.01 1401.00153.00 1086.00008.00 E115192 1104.00061.01 1401.00154.00 1086.00008.00 E115193 1104.00096.01 1401.00154.00 1086.00008.00 Go to fetco.com for the latest versions of all information P167 November 2017 Page 14...
  • Page 15 TANK ASSEMBLY, CBS1151 XXV+ 2 x 3kW/240VAC 1104.00095.01 TANK ASSEMBLY, CBS1151 XXV+ 5kW/240VAC 1104.00096.01 TANK ASSEMBLY, CBS1151 XXV+ 2 x 2.3kW/240VAC 1104.00097.01 TANK ASSEMBLY, CBS1151XXV+ 4kW/240VAC Go to fetco.com for the latest versions of all information P167 November 2017 Page 15...
  • Page 16: Parts Diagrams Cbs-1152V

    E115290 1101.00339.00 1104.00062.01 1401.00156.00 1086.00008.00 E115291 1101.00339.00 1104.00074.01 1401.00156.00 1086.00008.00 E115292 1101.00339.00 1104.00080.01 1401.00155.00 1086.00008.00 E115294 1101.00339.00 1104.00081.01 1401.00155.00 1086.00008.00 E115296 1101.00339.00 1104.00075.01 1401.00156.00 1086.00008.00 Go to fetco.com for the latest versions of all information P167 November 2017 Page 16...
  • Page 17 Hot Water Tank 3X5kW/240VAC 1104.00075.02 Hot Water Tank 3X4kW/240VAC 1104.00080.02 Hot Water Tank 2x3kW/240VAC 1104.00081.02 Hot Water Tank 2X5kW/240VAC B015280BN2 Brew Basket-Plastic B001280B1 Brew Basket-stainless steel- *Optional accessory Go to fetco.com for the latest versions of all information P167 November 2017 Page 17...
  • Page 18: Cbs-1151V+ Tank Assembly

    RELAY, SOLID STATE, 50A/480VAC, W/BUILD IN VARISTOR 1081.00042.00 STANDOFF, 1/4" HEX 1022.00068.00 INSULATION, TANK FRONT, CBS-2151 1022.00069.00 INSULATION, TANK BACK, CBS-2151 1044.00004.00 LABEL, DANGER, HIGH VOLTAGE Go to fetco.com for the latest versions of all information P167 November 2017 Page 18...
  • Page 19: Cbs-1152V+ Tank Assembly

    NUT, HEX, #6-32, UNDERSIZED, ZINC PLATED 1003.00140.00 ALUMINUM BRACKET FOR SSR 1052.00033.00 RELAY, SOLID STATE, 50A/480VAC, W/BUILD IN VARISTOR 1081.00042.00 STANDOFF, 1/4" HEX 1044.00004.00 LABEL, DANGER, HIGH VOLTAGE Go to fetco.com for the latest versions of all information P167 November 2017 Page 19...
  • Page 20: Wiring Diagrams

    E115294 CBS-1152-XV+, 1Ph, 2+G, 2 X 5.0kW/240VAC, 200-240VAC, INTL 6.9 - 10.0 35.2 - 42.1 1401.00110.00 2 X 5.0 KW E115296 CBS-1152-XV+, 3Ph, 4+G, 3 X 4.0kW/240VAC, 240/415VAC, INTL 1401.00112.00 Go to fetco.com for the latest versions of all information P167 November 2017 Page 20...
  • Page 21 Go to fetco.com for the latest versions of all information P167 November 2017 Page 21...
  • Page 22 SKU DESCRIPTION: Amps Wiring Schematic Heaters Go to fetco.com for the latest versions of all information P167 November 2017 Page 22...
  • Page 23 21.2 - 25.4 1401.00100.00 2 X 3.0 KW INTL CBS-1151-XV+, 1Ph, 2+G, 2 X 2.3kW/240VAC, 200-240VAC, E115193 16.3 - 19.6 1401.00100.00 2 X 2.3 KW INTL Go to fetco.com for the latest versions of all information P167 November 2017 Page 23...
  • Page 24 Go to fetco.com for the latest versions of all information P167 November 2017 Page 24...

This manual is also suitable for:

Extractor v+ cbs-1151-xv+Extractor v+ cbs-1152-xv+

Table of Contents