FETCO COFFEE BREWER: CBS-1150 EXTRACTOR

TABLE OF CONTENTS

Specifications and Requirements ................................ 2
Rough-In Drawings ...................................................... 2
Electrical and Output Specifications ............................ 3
Starting The Brew ........................................................ 4
Enter Programming ...................................................... 4
Exit Programming & Save ............................................ 4
PROGRAMMING MENU LAYOUT .............................. 5
A PROGRAM ............................................................... 6
B GENERAL................................................................. 7
C INPUTS .................................................................... 8
D OUTPUTS ................................................................ 8
E OTHER ..................................................................... 8
F SAVE & EXIT ............................................................ 9
CONTACT INFORMATION
FETCO®
FOOD EQUIPMENT TECHNOLOGIES COMPANY
600 ROSE ROAD
LAKE ZURICH • IL • 60047-0429 • USA
INTERNET: www.fetco.com
©2017-2018 FOOD EQUIPMENT TECHNOLOGIES COMPANY
USER'S GUIDE & OPERATOR INSTRUCTIONS
CBS-1152-XV+
Error Codes .................................................................. 9
Operator Training ....................................................... 10
Cleaning & Maintenance ............................................ 10
Installation Guide........................................................ 11
Parts Diagram CBS-1151XV+ .................................... 14
Parts Diagram CBS-1152XV+ .................................... 16
CBS-1151XV+ Tank Assembly .................................. 18
CBS-1152XV+ Tank Assembly .................................. 19
Wiring Diagrams ......................................................... 20
PHONE: (800) 338-2699 (US & CANADA)
(847) 719-3000
FAX: (847) 719-3001
EMAIL: sales@fetco.com
techsupport@fetco.com
PATENTS: WWW.fetco.com/patents
P167
REV:000
V+
®
fetco.com
MARCH 2018

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the CBS-1150 EXTRACTOR V+ and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Fetco CBS-1150 EXTRACTOR V+

  • Page 1: Table Of Contents

    USER’S GUIDE & OPERATOR INSTRUCTIONS FETCO COFFEE BREWER: CBS-1150 EXTRACTOR ® ™ CBS-1151-XV+ CBS-1152-XV+ TABLE OF CONTENTS Specifications and Requirements ........ 2 Error Codes ..............9 Rough-In Drawings ............2 Operator Training ............10 Electrical and Output Specifications ......3 Cleaning &...
  • Page 2: Cbs-1151-Xv

    Field conversion is to be made only by licensed electrician. Disconnect equipment from power supply before service. Remove jumper between L2 and L3, and apply power to L3 Go to fetco.com for the latest versions of all information P167 March 2018...
  • Page 3: Electrical And Output Specifications

    3 X 3.0 kW 230/400 12.4 22.5 gal/85 liters 3L,N,PE Terminal Block (CE) E115262 3 X 5.0 kW 230/400 3L,N,PE 14.1 20.4 38.3 gal/145 liters Go to fetco.com for the latest versions of all information P167 March 2018 Page 3...
  • Page 4: Starting The Brew

    EXIT (“F”) toggle to the EXIT- toggle to the SAVE toggle to the SAVE- and EXIT to screen appears YES screen screen YES screen OPERATING MODE Go to fetco.com for the latest versions of all information P167 March 2018 Page 4...
  • Page 5: Programming Menu Layout

    A menu remaining (3 or 6) “A” programming keys. permanent) access screen menus. Make any See SAVE & EXIT in changes as required previous table Go to fetco.com for the latest versions of all information P167 March 2018 Page 5...
  • Page 6: A Program

    The table above shows in position A20 that a BATCH A2 BATCH A5 button position can be made active or inactive. Position A1 does not display this step BATCH A3 BATCH A6 Go to fetco.com for the latest versions of all information P167 March 2018 Page 6...
  • Page 7: B General

    USER SELECTABLE OPTION: BREW AT TEMP: OFF (Not recommended) Unit will operate at cold temperature Allows brewing at any temperature above 77°C/170°F Below 70°C/170°F-the red colored ready lights switch turn off Go to fetco.com for the latest versions of all information P167 March 2018 Page 7...
  • Page 8: C Inputs

    Demonstrates the controls for training. Brewer will not DEMO Mode DEMO ON/OFF Will need reboot brew when in demo mode. Reset in E8 to “OFF” to exit Go to fetco.com for the latest versions of all information P167 March 2018 Page 8...
  • Page 9: F Save & Exit

    Brew basket must be in place Insert brew basket into brewer rails to BSKT enable brewer This is a Insert Brew Basket SAFETY FEATURE Go to fetco.com for the latest versions of all information P167 March 2018 Page 9...
  • Page 10: Operator Training

    5. Do not attempt to move hot beverage equipment once it is filled. Drain equipment before moving. 6. FETCO commercial coffee brewers prepare large amounts of coffee or tea in a single batch using very hot water 7. Commercial coffee brewers provides very hot water from the spray head, brew basket and faucet when it is pulled.
  • Page 11: Installation Guide

    4. Damages resulting from improper installation are not covered by the warranty, and will void the warranty. Electrical: 1. All FETCO brewers require an electrical ground wire. Installation without grounding is dangerous. 2. Note Equipotentiality Terminal, if present, (To identify the terminals which, when connected together, bring the various parts of equipment or of a system to the same potential, not necessarily being the earth (ground) potential, e.g.
  • Page 12 Do not operate if unit has been submerged or saturated with water. Labels and warnings for hot beverage equipment For BACK PANEL of equipment (1046.00035.00) Go to fetco.com for the latest versions of all information P167 March 2018 Page 12...
  • Page 13 1082.00123.00 SCREW #8-15 X 0.75"TRUSS HEAD; SELF TAPPING 1102.00043.00 CASCADE SPRAY DOME CBS-2050/60'S 1000.00108.00 Brew valve rebuild kit CONTAINS: PLUNGER SPRING LARGE BREW VALVE DIAPHRAGM Go to fetco.com for the latest versions of all information P167 March 2018 Page 13...
  • Page 14: Parts Diagram Cbs-1151Xv

    1086.00031.00 E115162 1104.00096.01 1401.00159.00 1086.00031.00 E115180 1104.00095.01 1401.00152.00 1086.00008.00 E115190 1104.00097.01 1401.00153.00 1086.00008.00 E115191 1104.00095.01 1401.00153.00 1086.00008.00 E115192 1104.00061.01 1401.00154.00 1086.00008.00 E115193 1104.00096.01 1401.00154.00 1086.00008.00 Go to fetco.com for the latest versions of all information P167 March 2018 Page 14...
  • Page 15 TANK ASSEMBLY, CBS1151 XV+ 2 X 3KW/240VAC 1104.00095.01 TANK ASSEMBLY, CBS1151 XV+ 5KW/240VAC 1104.00096.01 TANK ASSEMBLY, CBS1151 XV+ 2 X 2.3KW/240VAC 1104.00097.01 TANK ASSEMBLY, CBS1151 XV+ 4KW/240VAC Go to fetco.com for the latest versions of all information P167 March 2018 Page 15...
  • Page 16: Parts Diagram Cbs-1152Xv

    1086.00031.00 E115280 1104.00062.01 1401.00148.00 1086.00008.00 E115290 1104.00062.01 1401.00156.00 1086.00008.00 E115291 1104.00074.01 1401.00156.00 1086.00008.00 E115292 1104.00080.01 1401.00155.00 1086.00008.00 E115294 1104.00081.01 1401.00155.00 1086.00008.00 E115296 1104.00075.01 1401.00156.00 1086.00008.00 Go to fetco.com for the latest versions of all information P167 March 2018 Page 16...
  • Page 17 HOT WATER TANK 3X5KW/240VAC 1104.00075.02 HOT WATER TANK 3X4KW/240VAC 1104.00080.02 HOT WATER TANK 2X3KW/240VAC 1104.00081.02 HOT WATER TANK 2X5KW/240VAC B015280BN2 BREW BASKET-PLASTIC (STANDARD) B001280B1 BREW BASKET-STAINLESS STEEL- (OPTIONAL) Go to fetco.com for the latest versions of all information P167 March 2018 Page 17...
  • Page 18: Cbs-1151Xv+ Tank Assembly

    ALUMINUM BRACKET FOR SSR 1052.00033.00 RELAY, SOLID STATE, 50A/480VAC 1081.00042.00 STANDOFF, 1/4" HEX 1022.00068.00 INSULATION, TANK FRONT 1022.00069.00 INSULATION, TANK BACK 1044.00004.00 LABEL, DANGER, HIGH VOLTAGE Go to fetco.com for the latest versions of all information P167 March 2018 Page 18...
  • Page 19: Cbs-1152Xv+ Tank Assembly

    LOCKWASHER, #6 SCREW , INTL TOOTH 1084.00010.00 NUT, HEX, #6-32, UNDERSIZED, ZINC PLATED 1003.00140.00 ALUMINUM BRACKET FOR SSR 1052.00033.00 RELAY, SOLID STATE, 50A/480VAC 1081.00042.00 STANDOFF, 1/4" HEX Go to fetco.com for the latest versions of all information P167 March 2018 Page 19...
  • Page 20: Wiring Diagrams

    Wiring Diagrams Go to fetco.com for the latest versions of all information P167 March 2018 Page 20...
  • Page 21 Go to fetco.com for the latest versions of all information P167 March 2018 Page 21...
  • Page 22 Go to fetco.com for the latest versions of all information P167 March 2018 Page 22...
  • Page 23 Go to fetco.com for the latest versions of all information P167 March 2018 Page 23...
  • Page 24 Go to fetco.com for the latest versions of all information P167 March 2018 Page 24...
  • Page 25 End of section notes...
  • Page 26 End of section notes...

This manual is also suitable for:

Cbs-1151-xv+Cbs-1152-xv+

Table of Contents