4.1.6
Exit
This option terminates the application.
4.2
Connection Setup
Set up the Communication Settings as shown below :
Select the Serial Port or the Ethernet port as applicable. For the Serial Port the baud rate
settings are fixed at 19200,N,8,1. The Ethernet mode uses port 10001 to communicate
with the EZ VMS Lite.
Each of the main menu options have several related sub menus to guide you through the
various sections of EZ VMS Lite programming.
4.3
Update Unit date and time
The current date and time of the EZ VMS Lite may be imported from the unit and
displayed by clicking the menu option "Update Unit Date & Time". An option to update
the current date and time of the unit is also provided.
The date and time information may be imported from the unit through the serial port or
through LAN port. The current date & time information is imported from the unit and
displayed on screen.
EZ VMS Lite
43