14.

TROUBLESHOOTING

In order to prevent an electrical shock, be sure to turn power off before performing work
by touching the interior parts of the product.
Be careful so as not to damage wirings Damaged wiring can cause an electrical shock or
short circuit accident.
For troubleshooting, first check the connection of wiring connectors.
PROBLEMS
When the main
The power is not ON.
SW is turned
ON, the machine
Incorrect power source/voltage.
is not activated.
The CIRCUIT PROTECTOR functioned due
to momentary over current.
The fuse is blown due to instantaneous
overload.
REPLACEMENT AND ADJUSTMENT OF FUSE
Be sure to use fuses meeting specified rating. Using fuses exceeding the
specified rating can cause a fire or electric shock.
PART NUMBER
514-5078-2000
WH HDF (60033UK)
514-5078-2000
WH HDF 60029-02UK)
514-5079-10000
XFMR (560-LGBH-UK)
514-5090-3000
FL UNIT (390-7001-30UK)
514-5078-5000
IEC INLET (EP1387)
CAUSE
LOCATION
2A T CERAMIC 20X5MM
2A T CERAMIC 20X5MM
10A T CERAMIC 32X6.3MM
3A T CERAMIC 25X6.3MM
5A T CERAMIC 20X5MM
COUNTERMEASURES
Firmly insert the plug into the outlet.
Make sure that the power
supply/voltage are correct.
Remove the cause of overload to reset
the circuit protector
After eliminating the cause of overload,
replace the Connector Board fuse.
TYPE & DETAILS
QTY
2