What Happens When You Press Enter - Elcometer Protovale 331 Operating Instructions Manual

Concrete covermeter
Hide thumbs Also See for Protovale 331:
Table of Contents

Advertisement

measure the bar size using the Orthogonal method - see "Measuring size of
reinforcement bars (orthogonal)" on page 29.
9. If the bar diameter and the autosize bar diameter correspond and you are
satisfied that the search head is directly over the reinforcement bar, either
move on to the next bar or press

6.3 What happens when you press Enter

1. The cover reading is entered into the current statistical analysis.
2. If a batch is open, the reading is saved into a memory location.
The Covermeter will then advance (scroll) to the next memory location.
When the last memory location of a row in a grid is reached, the
Covermeter will advance to the first memory location of the next row (Figure
12). When a batch is complete, the Covermeter closes the batch and exits
batching.
Refer to "The BATCH softkey" on page 44 for information on how to
navigate around a batch and review, delete, overwrite and skip memory
locations while you are taking readings.
3. The Covermeter will beep:
• Single beep - reading taken.
• Double beep - reading taken in last memory location of a row in a grid.
• Triple beep - reading taken in last memory location of the grid.
h
• Triple beep
been set (
Figure 12. Beeps ( ) and scrolling on a 6x3 grid batch
h. The LED in the search head will also flash to indicate an 'out of limits' reading.
(higher pitch) - reading taken is outside limits if limits have
MENU / SETUP / LIMITS).
A
B
1
2
3
M
EASURING DEPTH OF COVER
.
C
D
E
F
R
25