11 LIMITS

Low and High limits can be set by the user to monitor whether depth of cover is
within specifications.
MENU / SETUP / LIMITS
LOW LIMIT
LOW LIMIT ON
LOW LIMIT
Set the limit value and toggle the tick box to switch the limit on or off.
With limits switched on, when you take a reading which is within the limits, the
Covermeter will beep once. When you take a reading which is outside the limits,
the Covermeter will beep three times to warn you of an out-of-limit reading.
When batching is switched on and limits are switched on, readings in a batch
which are outside the limits are marked as follows:
Down arrow icon
Up arrow icon
20MM
if the reading is below the low limit.
if the reading is above the high limit.
HIGH LIMIT
HIGH LIMIT ON
HIGH LIMIT
R
L
IMITS
50MM
37