9 MEASURING SIZE OF REINFORCEMENT BARS (ORTHOGONAL)
Although the Covermeter includes the AutoSize feature (see page 28), a
separate 'orthogonal' SIZE function is included for accurate measurement of
bar size.
The orthogonal SIZE function is intended to be used to determine the diameter
of a (single) reinforcement bar. Although the associated cover will also be
displayed, this function is not intended to be used for scanning areas.
Orthogonal sizing can be performed at greater depths than the AutoSize
function.
The following sections describe how to use the SIZE function.
9.1 Before you start
•
Are you using the correct search head?
See "Search heads" on page 57.
•
What units of measurement do you want to use?
See "SETUP" on page 16.
9.2 Procedure
1. Connect the search head to the Covermeter.
2. Switch on the Covermeter.
3. Zero the Covermeter.
4. Set sound mode to 'locate' -
LOCATE.
5. Press the SIZE softkey. The display will show:
6. Adjust sensitivity - see "Adjusting sensitivity" on page 34.
7. Locate the exact position and orientation of the reinforcement bar using the
sound, the LED and the display as indicators - see "Locating reinforcement
bars" on page 19.
M
EASURING SIZE OF REINFORCEMENT BARS
MENU / SETUP / SOUND MODE /
R
(
)
ORTHOGONAL
29