OPERATION
Using Status LEDs
Use the status LEDs to monitor the media
converter operation in the network.
PWR
P(o)W(e)R Steady LED indicates
connection to external power.
TL1
T(wisted-pair) L(ink) 1: Steady
LED indicates a link on the
twisted-pair TELCO connection to
Converter #1.
FL1
F(iber) L(ink) 1: Steady LED
indicates a link on the fiber
connection to Converter #1.
AC1
AC(tivity) 1:
Flashing LED
indicates activity on Converter #1.
TL2
T(wisted-pair) L(ink) 2: Steady LED indicates a link on the
twisted-pair TELCO connection to Converter #2.
FL2
F(iber) L(ink) 2: Steady LED indicates a link on the fiber
connection to Converter #2.
AC2
AC(tivity) 2: Flashing LED indicates activity on Converter #2.
Using SNMP*
Use SNMP at an attached terminal or at a remote location to:
•
Monitor the media converter by monitoring:
Media Converter Power
Twisted-pair Link Status on Converter #1
Fiber Link Status on Converter #1
Activity on Converter #1
Twisted-pair Link Status on Converter #2
Fiber Link Status on Converter #2
Activity on Converter #2
•
Enter network commands that:
Enable/disable Autocross
*See the on-line documentation that comes with TRANSITION Networks
™
FocalPoint
software for applicable commands and usage.
PWR
AC1
TL1
FL1
FL2
TL2
7
FAULT ISOLATION
and
If the media converter fails, isolate and correct the fault by determining the
answers to the following questions and then taking the indicated action:
Is the P(o)W(e)R LED on the media converter illuminated?
1.
NO
•
Is the media converter inserted properly into the chassis?
•
Is the power cord properly installed in the chassis and at the
external power source?
•
Does the external power source provide power?
•
Contact Technical Support: (800) 260-1312.
YES
•
Proceed to step 2.
Is the T(wisted-pair) L(ink) 1 LED illuminated?
2.
NO
•
Check the twisted-pair TELCO cables for proper connection.
•
Ensure that the twisted-pair copper TELCO cable distance does NOT
EXCEED 60 meters.
•
Contact Technical Support: (800) 260-1312.
YES
•
Proceed to step 3.
Is the F(iber) L(ink) 1 LED illuminated?
3.
NO
•
Check the fiber cables for proper connection.
•
Verify that the TX and RX cables on media converter are connected
to RX and TX ports, respectively, on the other device.
•
Contact Technical Support: (800) 260-1312.
YES
•
Proceed to step 4.
4.
Is the AC(tivity) 1 LED illuminated?
NO
•
Verify that data is being sent from the external devices.
•
Verify that all external devices are set to forced 100 Mb/s full-duplex
for full-duplex operation.
•
Contact Technical Support: (800) 260-1312.
YES
•
Proceed to step 5.
5.
Is the T(wisted-pair) L(ink) 2 LED illuminated?
NO
•
Check twisted-pair TELCO cables for proper connection.
•
Ensure that the twisted-pair copper TELCO cable distance does NOT
EXCEED 60 meters.
•
Contact Technical Support: (800) 260-1312.
YES
•
Proceed to step 6.