INSTALLATION

Install Slide-In-Module
NOTE: Before cabling the Slide-In-Module media converters installed in the
CPSMC1850 chassis, refer to the diagrams below. Determine the connections
to be made from TELCO Connector #2 to Slide-In-Module slot location #7
through #12 (upper port or lower port). Then determine connections to be
made from TELCO Connector #1 to Slide-In-Module slot location #13 through
#18 (upper port or lower port).
Media
Conversion
Center
TX
PWR
PWR
LKF
Power
1
RXF
In Use
RX
LNK
RXC
LKC
TX
Power
2
RESET
In Use
RX
MCCM10
MGMT MASTER
CETTF100
CDFTF100
CDFTF100
1
2
3
4
5
6
7
Telco Connector #2
CAUTION: Wear a grounding device and observe electrostatic discharge
precautions when installing Media Converter Slide-in-Module in the Media
Conversion Center. Failure to observe this caution could result in damage to, and
subsequent failure of, the Media Converter Slide-in-Module.
CAUTION: Any Slide-in-Module installation slot in which a Slide-in-Module is
NOT installed MUST have a protective plate installed in the installation
location. Failure to observe this caution will void Class A compliance.
To install the Media Converter Slide-in-Module into the CPSMC1850 chassis:
1.
Carefully slide the Media Converter Slide-in-Module into the installation
slot, aligning the Media Converter Slide-in-Module with the installation
guides.
NOTE: Ensure that the Slide-in-Module is firmly seated against the
backplane.
2.
Secure the Slide-in-Module by securing the panel fastener screw
(attached to the Slide-in-Module) to the chassis front.
3.
Install the protective plate at ANY Slide-in-Module installation slot in
which a Media Converter Slide-in-Module is not installed by securing
the attached protective plate panel fastener screw to the chassis front.
CDFTF100
CDFTF100
CDFTF100
CDFTF100
CDFTF100
CDFTF100
CDFTF100
CDFTF100
8
9
10
11
12
13
14
15
16
17
CDFTF100
Telco Connector #1
INSTALLATION
Install Cable
NOTE: The media converter does not support autonegotiation. Set the
external devices to forced 100 Mb/s full-duplex for half-duplex operation.
TELCO COPPER
CAUTION: Ensure that the twisted-pair copper TELCO cables do not
exceed 60 meters in length. Failure to observe this caution could cause
data transfer to fail.
1.
CDFTF100
18
2.
3.
4.
FIBER
1.
2.
RX
3.
Power the Media Converter
NOTE: The Slide-In-Module is powered through the Media Conversion
Center.
5
6
(continued)
Locate the 100BASE-TX cable with the male 50-pin TELCO
connector at one end and with twelve (12) RJ-45 connectors at
other end (available from TRANSITION Networks, P/N 21HC45-6).
(Alternatively, the male 50-pin TELCO connector at both ends;
available from TRANSITION Networks, P/N 21HC21-6; may also
be used.)
Connect the male 50-pin TELCO cable connector to the female 50-
pin TELCO connector at the chassis back.
Connect the twelve (12) RJ-45 connectors or the male 50-pin
TELCO cable connector at the other cable end to the 100BASE-TX
TELCO device(s).
Repeat steps 3 and 4 to connect the second 100BASE-TX TELCO
cable to the second 50-pin TELCO connector at the chassis back.
Locate or build a 100BASE-FX-compliant fiber cable with male two-
stranded TX to RX connectors installed at both ends.
Connect the cable with the connector installed at TX location on
media converter to the RX location on the attached device.
TX
Connect the cable with the connector installed at the RX location
on the media converter to the TX location on the attached device.
TX
RX
CDFTFxxxx-10x