Galvin Specialised Safe-Cell TZ-FLOWTPANMDT Product Installation Manualline

Ducted dual flush pan assembly for mains with controller

Advertisement

Quick Links

®
Safe-Cell
Ducted Dual Flush Pan Assembly
for Mains with Controller
PRODUCT CODE:
TZ-FLOWTPANMDT
-
SPECIFICATIONS
®
-
Safe-Cell
Electronic dual flush pan assembly provides the complete anti-vandal, anti-ligature
solution. The unique electronic valve assembly provides a precise delivery of water, and is
specifically designed for prisons, mental health facilities and other custodial establishments.
-
4mm thick, exposed stainless steel faceplate to suit back mounted applications and steel face plate
features push activation buttons. Plates have no front penetrations and are fixed from the duct.
-
Solenoid is a Watermarked high flow, low-pressure loss control valve. The body and outer casing are
made from Nylon and features a stainless steel plunger and nitrile diaphragm.
®
Safe-Cell
Electronic controller is a 24V AC electronic control system allowing connection of up to 2
-
button inputs and up to 2 solenoids (single solenoid only for flushing units). Controller is pre-
programmed and ready to use. The solenoids will open for a specific time once the appropriate
button is pressed. The standard program can be modified to suits individual needs. To modify the
operation settings a compatible Android device with Bluetooth is required.
TECHNICAL DATA
Power Supply
Solenoid
Sensor
Controller
Finish (user)
Minimum Delivering Flow Rate (Litres per second)
* - The minimum pipe size serving the flush valve shall be DN 25.
NOTE: Galvin Specialised continually strive to improve their products. Specifications may change without notice.
Type
Input
Output
Cable length
Input Voltage
Power Consumption
Cable length
Inlet
Connection
Outlet
Min
Pressure Range
(kPa)
Max
Min
Temperature (°C)
Max
Type
Activation
Connections
Cable length
Input Voltage
Program type
Connections
Version 1, 18 December 2020, Page 1 of 12
Transformer
230-240V – 50Hz
24V AC 0.9AMPS 22VA
3m
24V AC – 50Hz
4.5VA
5m
1" BSP - Female
2" BSP - Male
70
500
2
40
IP68 24V
Push Button
2 pin connector
5m
24V AC
Flowmatic
2 pin connectors
Stainless Steel
1.5 @ 350kPa dynamic pressure (flow)

Advertisement

loading

Summary of Contents for Galvin Specialised Safe-Cell TZ-FLOWTPANMDT

  • Page 1 Minimum Delivering Flow Rate (Litres per second) 1.5 @ 350kPa dynamic pressure (flow) * - The minimum pipe size serving the flush valve shall be DN 25. NOTE: Galvin Specialised continually strive to improve their products. Specifications may change without notice.
  • Page 2: Pre-Installation

    24 hours from the time of the first use. GENERAL INSTALLATION REQUIREMENTS Do not cut the wires or extended the existing leads without using a correct lead extension from Galvin Specialised, as this will void warranty. Suitable access to the service of all components must be provided.
  • Page 3 Version 1, 18 December 2020, Page 3 of 12 Mounting Details Face plate cut out position Cut out details for face plate − Locate push button face plate at a suitable distance from Faceplate to suit wall thickness between 30mm to the pan (we recommend 300mm from the centre of the 240mm.
  • Page 4: Installation

    Version 1, 18 December 2020, Page 4 of 12 INSTALLATION Avoid common installation errors : Incorrect supply pipe size installed. Lines not flushed before installation. Non-compliance to Australian Standards. No access for service. Water pressure not tested before installation Valve not commissioned properly. Plastic Pipe (In many brands of plastic pipe and associated fittings the internal diameter is not equivalent to copper).
  • Page 5 Version 1, 18 December 2020, Page 5 of 12 Note: Controller must be mounted away from any moisture or potential water splashing. Connect water 4. Mount control module − Attach the control module to a flat surface away − It is recommended that the cold water inlet is from any possible splashing or moisture using a minimum DN25 and has a minimum flow rate of 1.5 liters/second.
  • Page 6 Check for correct operation. the output side. − If extension leads are required, please contact Galvin Specialised. The connection of this product to mains power supply should be undertaken by a Do not cut the leads. If the leads are too competent person and should confirm to local Wiring Regulation –...
  • Page 7 Version 1, 18 December 2020, Page 7 of 12 CONTROLL MODULE PROGRAM MODIFICATION Required to make changes to the controller settings : Android device (e.g. smartphone, tablet). Installed from PlayStore ‘Flowmatic system’ software. 1. Establish Bluetooth connection 2. Entering the pin −...
  • Page 8 Version 1, 18 December 2020, Page 8 of 12 3. Changing controllers settings Open the Flowmatic system’ app. The device − 4. Setting screen overview. will appear on the screen. with Mac Address Upper function buttons. By pressing the ‘Get −...
  • Page 9 Version 1, 18 December 2020, Page 9 of 12 5. Type of controller (left drop-down menu) 6. Chanel select (middle drop-down menu) For the PB2 controller only the PB2 The PB2 controller has built in two channels. They selection is correct. Please do not change may be controlled independently or one of the the selection for the PB2 controller channels to be used as half flush and second...
  • Page 10 Version 1, 18 December 2020, Page 10 of 12 9. Settings for pans. The default configuration for a pan is two 10. Settings for shower. buttons and one or two solenoids. By PB2 controller is capable of controlling two buttons marking the ‘Link pans’...
  • Page 11: Troubleshooting

    Version 1, 18 December 2020, Page 11 of 12 TROUBLE SHOOTING PROBLEM CAUSE RECTIFICATION No Power Check power is reaching transformer Outer ring on push button not Ensure all leads are firmly pushed into illuminated. Leads not connected correctly connectors No power Check power is reaching transformer Check electrical connections, Replace...
  • Page 12: Warranty

    Version 2, 18 December 2020, Page 12 of 12 Maintenance Instructions Solenoid Valve: − Turn the water supply off and activate the push button to drain as much water from the installation as possible, and then turn the power off at the GPO. −...