Ducted dual flush pan assembly for mains with controller

Advertisement

5. Type of controller (left drop-down menu)
-
For the PB2 controller only the PB2
selection is correct. Please do not change
the selection for the PB2 controller
7. Designated feature drop-down menu
The PB2 controller can be used for
-
showers, basins and pans. Depend of the
feature selection setting slides will appear.
(e.g. there is only 'Run' time to be set for
basin, 'Run' and 'Lockout' times for pans
and there is 'Shower end warning' time for
shower)
Version 1, 18 December 2020, Page 9 of 12
6. Chanel select (middle drop-down menu)
-
The PB2 controller has built in two channels. They
may be controlled independently or one of the
channels to be used as half flush and second
channel as full flush for a pan.
8. Settings for Basin
Set the channel no. of the solenoid and activation
-
button to be changed.
Set the required water flow 'Run time' in seconds
-
for the basin.
Set the Hygiene flush parameters if required.
-
-
Press 'Upload' to upload the settings to the
controller.
The controller can be used in configurations: one
-
button – one solenoid, one button – two solenoids
or two buttons – two solenoids.