Lead free ss316 45 push button drinking bubbler tap (4 pages)
Summary of Contents for Galvin Specialised Ezy-Drink CP-BS TD15EB
Page 1
Input Voltage 6 V DC Power Consumption 1/2” BSP - Female Inlet Connection 1/2” BSP - Male Outlet Solenoid Pressure Range (kPa) Temperature (°C) Finish Chrome NOTE: Galvin Specialised continually strive to improve their products. Specifications may change without notice.
Page 2
Rough-In Dimensions INSTALLATION IMPORTANT: Galvin Specialised products must be installed in accordance with these installation instructions and in accordance with AS/NZS 3500, the PCA and your local regulatory requirements. Water and/or electrical supply conditions must also comply to the applicable national and/or state standards. Failing to comply with these provisions shall void the product warranty and may affect the performance of the product.
Page 3
Version 1, 16 June, Page 3 of 4 3. Fit Piezo Button 4. Connect Piezo Button, Solenoid and Battery − − Install piezo button as shown. Connect Piezo button, the solenoid & the battery to the − Ensure the correct coloured washer is fitted eletronic control unit.
Page 4
Version 1, 16 June, Page 4 of 4 SET WATER FLOW DURATION Controller Button − Switch the power to the controller off. − Once again, push the piezo button 5 times. − The red light on the controller should now be lit. After 5 seconds switch the power on.