Service Mode Keyboard Functions; How To Enter/Exit The Service Mode; Service Mode Keys, Displays & Indicator Lights - Planmeca Proline EC pan Technical Manual

Table of Contents

Advertisement

Chapter B - KEYBOARD FUNCTIONS & MODES

3 SERVICE MODE KEYBOARD FUNCTIONS

CAUTION
Some of the functions in the service mode may be fatal to the unit's proper operation.
Never use special service mode functions if you are not familiar with how they operate.
The service mode is only intended for the trained technician.
CAUTION
Operating the exposure switch will immediately start the X-Ray generator.
NOTE
The operations of the rotation and cassette motors are disabled in this mode to allow
generator operation without movements.
For further diagnosis of the equipment operation a separate service mode has been provided.
Various kinds of adjustments and calibrations can also be made in this operating mode.
There are also some special control and display modes that are not normally available but
which can be entered by certain control sequences. In this section it is explained what opera-
tions can be achieved with the keys and which indications appear on the displays.

3.1 How to enter/exit the service mode

Press the CTL-key and simultaneously press and hold down the hidden key (to the right of the
panoramic mode selection key) until the temperature of the tubehead appears on the display
(about four seconds). The ready key indicator light will start to flash. This indicates that you
have entered the service mode.
CAUTION
Some of the functions in the service mode may be fatal to the unit's proper operation.
Never use special service mode functions if you are not familiar with how they operate.
To exit the service mode press the hidden key briefly.
3.2 Service mode keys, displays & indicator lights
Some of the keys, displays and indicator lights have different meanings in the service mode.
In the special function mode some of the indicator lights have third meaning. The special
function mode is entered by pressing the CTL-key.
KEYS AND DISPLAYS
CTL
B-6 Planmeca Proline EC X-ray unit
+
Hidden
CTL
key
CTL key is used either to clear an error indication, when no
further actions are taken, or to give the other keyboard
keys special functions.
The main display shows the tubehead temperature, an
error code or waiting time (blinking).
SERVICE MODE KEYBOARD FUNCTIONS
FUNCTION
FOR DETAILS, REFER
TO
"Control
(CTL)
-key
and indicator light" on
page B-9
"Main
display"
on
page B-7
Technical Manual