6.
Remove the screws (3) and the LSU
Figure 3 LSU Removal (Top View)
Replacement
NOTE: Tapered Plastic Screws and Round Machine Screws are used to hold the PWB to the
frame. Make sure that the Plastic Screws go into plastic components and Machine Screws go
into the metal frame.
Install the components in the reverse of removal.
Xerox® WorkCentre® 3025 Multifunction Printer Service Manual
(Figure
3).
Screws
REP 1.13 Feed Rolls and Retard Pad
Parts List on PL 5.3 and PL 5.7
Removal
1.
Switch Off the Printer and unplug the Power Cord.
2.
Remove the Print Cartridge.
3.
Remove the Middle Cover (REP 1.4).
4.
Perform the following
(Figure
a.
Disconnect the Drive Motor connector (1).
b.
Remove the inside LSU cover screws (2).
Connector
Figure 1 Motor Connector and LSU Cover Screws (Front View)
June 2014
4-23
1):
Screw
REP 1.12, REP 1.13
Repairs