Xerox WorkCentre 3025BI Service Manual page 63

Hide thumbs Also See for WorkCentre 3025BI:
Table of Contents

Advertisement

5.
Remove the Plastic Shield (2 screws)
Screws
Figure 2 Plastic Shield Screws
Xerox® WorkCentre® 3025 Multifunction Printer Service Manual
(Figure
2).
NOTE: Be careful not to lose the High Voltage Spring Contacts when removing the SMPS
/ HVPS PWB from the Frame.
6.
Remove the LVPS / HVPS PWB
a.
Disconnect the Fuser and Main PWB connectors.
b.
Remove the screws (6) and the LVPS / HVPS PWB.
Connectors
Figure 3 SMPS /HVPS PWB Screws
Replacement
NOTE: Tapered Plastic Screws and Round Machine Screws are used to hold the PWB to the
frame. Make sure that the Plastic Screws go into plastic components and Machine Screws go
into the metal frame.
Install the components in the reverse of removal.
June 2014
4-11
(Figure
3).
Screws
Screws
Repairs
REP 1.6

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Workcentre 3025ni

Table of Contents