Entering information text

SMS command "info"
Information text to identify the heating
system (e.g. name of the system opera-
tor, location of the system). This text is
sent by SMS to clearly identify systems,
e.g. within a fault or warning message.
Text input is limited to a max. of 30 char-
acters; any more will be ignored.
Example:
SMS from the user
1111þinfoþHeating system
SMS command "ditext"
Information text for describing the appli-
ance at the digital input or its function.
This text is sent by SMS to clearly iden-
tify systems, e.g. within a fault or warning
message.
Text input is limited to a max. of 30 char-
acters; any more will be ignored.
Example:
Monitoring the fuel oil level.

Entering a mobile phone number

SMS command "mobnr1" and "mobnr2"
It is advisable to enter the emergency
call number of a heating contractor or
service company as the second mobile
phone number "mobnr2". This company
should be contracted to maintain the
heating system. The number of the jani-
tor or other person who can be reached
with an alarm or fault message can also
be used.
Reply SMS from the Vitocom 100
1111 INFO Heating system OK
Note
Scan see page 31.
SMS from the user
1111þditextþLow oil level
Reply SMS from the Vitocom 100
1111 DITEXT Low oil level OK
Note
Scan see page 31.
Example:
Enter 2 mobile phone numbers to be
notified.
Note
Applies to both mobile phone numbers.
SMS from user:
1111þmobnr1þ01791234567
SMS commands