Viessmann VITOTROL 300B Installation And Service Instructions For Contractors

Viessmann VITOTROL 300B Installation And Service Instructions For Contractors

Remote control for heat pump control unit

Advertisement

Quick Links

VIESMANN
Installation and service
instructions
for contractors
Vitotrol 300B
Remote control for heat pump control unit Vitotronic 200,
type WO1C
For applicability, see the last page
VITOTROL 300B
Please keep safe.
5623 681 GB
7/2013

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the VITOTROL 300B and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Viessmann VITOTROL 300B

  • Page 1 VIESMANN Installation and service instructions for contractors Vitotrol 300B Remote control for heat pump control unit Vitotronic 200, type WO1C For applicability, see the last page VITOTROL 300B Please keep safe. 5623 681 GB 7/2013...
  • Page 2 Safety instructions Safety instructions Please follow these safety instructions closely to prevent accidents and mate- rial losses. Safety instructions explained ■ Codes of practice of the relevant trade associations. Danger ■ All current safety regulations as This symbol warns against the defined by DIN, EN, DVGW, VDE and risk of injury.
  • Page 3 Repairing components that fulfil a safety function can compromise the safe operation of your sys- tem. Defective components must be replaced with genuine Viessmann spare parts. Auxiliary components, spare and wearing parts Please note Spare and wearing parts that have not been tested together with the system can compromise its function.
  • Page 4: Table Of Contents

    Index Index Installation instructions Installation sequence Installation site...................... Installing and connecting the Vitotrol 300B............Connecting several remote control units.............. Fitting the programming unit................. Removing the programming unit................Service instructions Commissioning Configuring the Vitotrol 300B................Message displays....................10 Specification....................... 12 Parts list Ordering parts......................
  • Page 5: Installation Sequence

    – On an internal wall in the main living room, approx. 1.5 m from the floor. Note – Away from windows or doors. If the Vitotrol 300B cannot be installed in – Not above radiators. a suitable location, connect the room – Not near heat sources (direct sun- temperature sensor, part no.
  • Page 6: Connecting Several Remote Control Units

    B 2-pole plug aVG (control unit or KM BUS distributor) Connecting several remote control units Up to 3 Vitotrol 300B can be connected Vitotrol 200 and Vitotrol 300B can be to the Vitotronic control unit. connected together to the Vitotronic con-...
  • Page 7 15 m A To the control unit (see connection C KM BUS distributor or on-site con- diagram on page 6) nection box B Vitotrol 300B Total length of all KM BUS cables max. 50 m Version 2 15 m 15 m...
  • Page 8: Fitting The Programming Unit

    Installation sequence Fitting the programming unit Please note Do not insert batteries into the Power is supplied by the control battery compartment. unit. Removing the programming unit...
  • Page 9: Commissioning

    ID. If, for example, a Vitotrol 300A was connected while a Vitotrol 300B was 1. Switch ON the power supply at the being replaced, the progress bar on Vitotronic control unit.
  • Page 10: Message Displays

    Message displays Message displays When there is a message, the associ- Call up the reason for the message by ated message symbol flashes on the dis- pressing OK. play. Pressing OK will display the message Fault text and message code. Fault Explanation of messages Fault "...
  • Page 11 Message displays Message displays (cont.) Calling up acknowledged messages Extended menu 2. "Fault", "Warning" or "Note"...
  • Page 12: Specification

    Specification Specification Power supply via KM BUS Power consumption 0.5 W Safety category IP rating IP 30 Permissible ambient temperature ■ during operation 0 to +40 °C ■ during storage and −20 to +65 °C transport Setting range for set room temperature 10 to 30 °C...
  • Page 13: Parts List

    Parts list Ordering parts The following information is required: 0003 Wiring chamber cover ■ Serial no. (see type plate) 0004 Separate pack ■ Position number of the part (from this 0005 Installation and service instruc- parts list) tions 0006 Operating instructions Standard parts are available from your local supplier.
  • Page 14 Parts list Ordering parts (cont.) 0001 0003 0002 0004 0005 0006...
  • Page 15: Certificates

    Certificates Declaration of Conformity We, Viessmann Werke GmbH&Co KG, D-35107 Allendorf, declare as sole respon- sible body, that the product Vitotrol 300B complies with the following standards: EN 55 014-1 EN 60 730-2-7 EN 55 014-2 EN 60 730-2-9 EN 60 730-1...
  • Page 16 Applicability Serial No.: 7501928 Viessmann Werke GmbH&Co KG Viessmann Limited D-35107 Allendorf Hortonwood 30, Telford Telephone: +49 6452 70-0 Shropshire, TF1 7YP, GB Fax: +49 6452 70-2780 Telephone: +44 1952 675000 www.viessmann.com Fax: +44 1952 675040 E-mail: info-uk@viessmann.com...