Installation Instructions

Vitotrol 300
Remote control for one heating circuit
Part No. 7133 382
Safety and Installation Requirements
Please ensure that these instructions are read and understood before commencing installation. Failure to comply with the
instructions listed below can cause product/property damage, severe personal injury, and/or loss of life.
Working on the equipment
The installation, adjustment, service,
and maintenance of this product must
be done by a licensed professional
heating contractor who is qualified and
experienced in the installation, service,
and maintenance of hot water boilers.
There are no user serviceable parts on
the boiler, burner, or control.
Installation Instructions
Certified as a component part
of Viessmann boilers only
5167 503 v1.1 01/2008
Ensure main power supply to
equipment, the heating system, and all
external controls has been deactivated.
Close main oil or gas supply valve. Take
precautions in both instances to avoid
accidental activation of power during
service work.
Ensure that the installation
literature of other components
is referred to.
H Weather-responsive operation only:
Installation in any given room.
H For operation with
room temperature sensing:
– Installation on wall of main living
area, approx. 5 ft. / 1.5 m above
floor,
– not in close vicinity of windows or
doors,
– not above radiators,
– not in close vicinity of heat sources
(direct sunlight, fireplace, TV etc.).
In the given room no other heating
control must be installed. If the
radiators have thermostatic radiator
valves, ensure that these are
completely open at all times.
For optimum heating comfort and
control each radiator or zone in another
room must be installed with individual
thermostatic radiator valves or zone
valves with room thermostats, if the
system is not perfectly balanced (i.e.
radiators or zones are over- or
undersized).
The remote control contains a built-in
room temperature sensor, which
measures the room temperature.
Cable to the remote control must not be
placed directly beside line voltage
wiring.
Connection: 2-wire cable,
AWG 18 copper

Advertisement

Table of Contents
loading

Summary of Contents for Viessmann Vitotrol 300

  • Page 1: Installation Instructions

    Cable to the remote control must not be placed directly beside line voltage wiring. Certified as a component part Connection: 2-wire cable, of Viessmann boilers only AWG 18 copper 5167 503 v1.1 01/2008...
  • Page 2: Remote Control Connection

    Montage und Anschluß Installation of Wall Mount Base 1. Strip cable and pull through bushing into wall mount base. 2. Secure wall mount base onto an electrical junction box or onto even wall. IMPORTANT Watch cable path to avoid damaging cable when drilling.
  • Page 3 Montage und Anschluß Connection of Several Remote Controls When connecting several remote controls to the control unit, use a KM-BUS Expansion Module (accessory, Part No. 7133 393) or install a junction box on site. Option 1 H If no other KM-BUS participants are connected aside from the remote controls, plug of the respective...
  • Page 4: Inserting Batteries

    Montage und Anschluß Adjusting the Coding Switch 1. Adjust coding switch on circuit board of the remote control according to table below. WARNING When handling the circuit boards no static discharge onto the components must take place. Avoid touching the circuit boards with hands.
  • Page 5: Mounting The Remote Control

    Montage und Anschluß Mounting the Remote Control 1. Insert remote control with a 90º angle to wall mount base into provided slot and fold down. IMPORTANT Ensure proper plug-in connection is established (apply pressure to top of housing). 2. Fold down remote control and snap into wall mount base.
  • Page 6: Technical Data

    Anhang Accessing Operating Status/Temperatures Refer to Vitotrol Operating Instructions Technical Data Power supply via KM-BUS Expansion Module Power consumption: 0.5 W Max. ambient temperature H at operation: 32 to 108 ºF / 0 to 40 ºC – 4 to 149 ºF / H when storing or transporting: –20 to 65 ºC...
  • Page 7 Anhang...
  • Page 8 Anhang Viessmann Manufacturing Company (U.S.) Inc. Viessmann Manufacturing Company Inc. 45 Access Road 750 McMurray Road Warwick, Rhode Island • 02886 • USA Waterloo, Ontario • N2V 2G5 • Canada Tel. (401) 732-0667 • Fax (401) 732-0590 Tel. (519) 885-6300 • Fax (519) 885-0887 www.viessmann-us.com •...

Table of Contents