Coordinate Measurement And Outputting The Data - Sokkia iM-50 Series Operator's Manual

Sokkia
Table of Contents

Advertisement

2. Allocate the [HVDOUT-T] or [HVDOUT-S] softkey to the
OBS mode screen.
"33.11 Allocating Key Functions"
• Pressing the softkey outputs data in the following format.
[HVDOUT-T]: GTS format
[HVDOUT-S]: SET format
3. Sight the target point.
4. Press [HVDOUT-T] or [HVDOUT-S] to measure the
distance and output the data to peripheral equipment.
5. Press [STOP] to stop outputting data and return to OBS
mode.

12.5 Coordinate Measurement and Outputting the Data

The following explains coordinate measurement and the features used to output measurement data to a
computer or peripheral equipment.
 Setting procedures: "9. CONNECTING TO EXTERNAL DEVICES"
Communication cables: "38. ACCESSORIES"
Output format and command operations: "Communication manual"
PROCEDURE
1. Connect iM and host computer.
2. Allocate the [NEZOUT-T] or [NEZOUT-S] softkey to the
OBS mode screen.
"33.11 Allocating Key Functions"
• Pressing the softkey outputs data in the following format.
[NEZOUT-T]: GTS format
[NEZOUT-S]: SET format
3. Sight the target point.
4. Press [NEZOUT-T] or [NEZOUT-S] to measure the
distance and output the data to peripheral equipment.
• When the Distance Measurement mode is set to "Tracking" in
the EDM Settings, the measured data cannot be output by
pressing [NEZOUT-T].
5. Press [STOP] to stop outputting data and return to OBS
mode.