Column Offset Measurement - Sokkia iM-50 Series Operator's Manual

Sokkia
Table of Contents

Advertisement

20.5 Column Offset Measurement

Find distance and coordinates of the center of the column.
If circumscription point (P1) and two circumscription points (P2, P3) of a column can be measured directly, the
distance to the center of the column (P0), coordinates and azimuth angle are calculated and displayed.
• The azimuth angle of the center of the column is 1/2 of total azimuth angle of circumscription points (P2) and
(P3).
PROCEDURE
1. Enter the instrument station data.
"13.1 Entering Instrument Station Data and Azimuth
Angle"
2. Press [OFFSET] in page three of OBS mode to display
<Offset>.
3. Select "Offset Clum" in <Offset>.
4. Sight the circumscription point (P1) and press [MEAS] to
begin measurement.
The measurement results are displayed. Press [YES].
• When [HVD] is pressed, display mode is switched from
coordinates to SD, ZA, HA-R.
5. Sight the left circumscription point (P2) and press [OK].
Offset Clum
M e a s u r e 1 s t P t .
Confirm?
ZA
HA-R
M e a s . L e f t P t . O K ?
92
20. OFFSET MEASUREMENT
C
HVD
MEAS
NO
YES
HVD
C
OK

Advertisement

Table of Contents
loading

This manual is also suitable for:

Im-52Im-55

Table of Contents