2. Select "Occ.orien." to set the instrument station data and
azimuth angle of the backsight point.
"13.1 Entering Instrument Station Data and Azimuth
Angle PROCEDURE Reading in Registered Coordinate
Data"
3. Select "S-O data". <S-O Coord> is displayed.
4. Enter the coordinates of the setting-out point.
• When [LOAD] is pressed, registered coordinates can be
recalled and used as setting-out coordinates.
"13.1 Entering Instrument Station Data and Azimuth
Angle PROCEDURE Reading in Registered
Coordinate Data"
• Pressing [DISP] switches between the distance input
modes.
5. Press [OK] to set the setting-out data.
• The tilt screen is displayed if the instrument is out of level.
Level the instrument.
"7.2 Levelling"
6. The difference in the distance and angle calculated with the
set instrument station and the target point is displayed.
Rotate the top of the instrument until "dHA" is 0° and place
the target on the sight line.
7. Press [MEAS] to begin setting-out measurement.
The target and the distance of the point to be set out is
displayed (S-OΔ HD).
15. SETTING-OUT MEASUREMENT
S-O
Occ.Orien
S-O data
Observation
EDM
S-O Coord
HR
LOAD
S-O HD
H
H
LOAD
S-O HD
dHA
HD
ZA
HA-R
REC
S-O HD
dHA
HD
ZA
HA-R
61
OK
DISP
40.0000
DISP
OK
C
MEAS
DISP
C