Items set and options (*: Factory setting)
Input order
Stn.ID Incr. (station ID increment)
Intersection
Input order
The input order of point name and code in recording screens can be selected.
Intersection
Select a suitable intersection type in advance.
"23. INTERSECTIONS"

33.6 Instrument Conditions - Power

Select "Inst. Config" in Config mode and select "Power supply".
Instr.config
Power supply
Instrument
Unit
Password
Date and time
Items set and options (*: Factory setting)
Power off
Resume
EDM eco mode
Power-saving automatic cut-off
To save power, power to the iM is automatically cut off if it is not operated for the selected time.
Resume function
When the Resume function is set to "On" and the power is switched off and then on again, the screen
appearing before the instrument was switched off, or a prior screen is redisplayed.
• When the Resume function is set to "Off", values input before the power is switched off will disappear.
EDM eco mode
Working duration will be longer by controlling and saving power to the EDM device.
• Time required to start distance measurement will be longer than usual when "EDM eco mode" is set to
"ON".
: PT  CODE*/CODE  PT
: 0 to 99999 (100*)
: Type A/Type B*
Power off
Resume
EDM eco mode : Off
: 5 min, 10 min, 15 min, 30 min*, No
: On*, Off
: On, Off*
186
33. CHANGING THE SETTINGS
:
3 0 m i n
: On