Commands and Responses for the Support Board
RSV
GCT
DNA
DA1
DA2
SNA
SA1
SA2
SID
7-2-2 Parameters

7-2-3 Data Formats

Commands
130
Note All settings below are shown in hexadecimal except where otherwise indicated.
Reserved. Set to 00.
Gateway count. Set to 02.
Destination network address. Specify within the following ranges.
00:
Local network
01 to 7F: Remote network (1 to 127 decimal)
Destination node number. Specify within the following ranges.
01 to 20: Node number in Controller Link network (1 to 32 decimal)
01 to 7E: Node number in SYSMAC NET network (1 to 126 decimal)
01 to 3E: Node number in SYSMAC LINK network (1 to 62 decimal)
FF:
Broadcast transmission
Destination unit address. Specify within the following ranges. (For computers,
10 Hex is added to the unit number for the Support Board.)
00:
PC (CPU Unit)
01:
User program
10 to 1F: Board for CPU Bus Unit or computer
FE:
Unit or Board connected to specified network
(Any Unit or Board in Controller Link, SYSMAC NET, or SYSMAC
LINK network)
Source network address. Specify within the following ranges.
00:
Local network
01 to 7F: Remote network (1 to 127 decimal)
Source node number. Specify within the following ranges.
01 to 20: Node number in Controller Link network (1 to 32 decimal)
01 to 7E: Node number in SYSMAC NET network (1 to 126 decimal)
01 to 3E: Node number in SYSMAC LINK network (1 to 62 decimal)
Source unit address. Specify within the following ranges.
00:
PC (CPU Unit)
01:
User program
10 to 1F: Board for CPU Bus Unit or computer
Service ID. Used to identify the processing generating the transmission. Set the
SID to any number between 00 and FF
All parameters are specified in hexadecimal unless otherwise specified. Where
decimal is specified, it is indicated by BCD.
The command code and text for the command are stored in memory as oper-
ands and the transmission is executed using the required parameters. The spe-
cific method depends on the programming method being used. Prepare the
transmission data from the command code to the end of the text (with the data
determined by the individual command), and execute the library function or
driver call for message transmission. There are two bytes available for the com-
mand code and 0 to 2,000 bytes for the text.
Command
Text
code
Section
7-2