3.1.12. System Security

Select "Basic Config" and System Security" and then "System Security" to open the
screen shown in Figure 3-12. On this screen, you can configure the various settings
for accessing this switch for configuration and management.
Screen Description
Console
Displays the idle timeout settings (in minutes) for terminating a console-con-
nected session if no input is made. The factory default setting is 5 minutes.
Telnet
Displays the idle timeout settings (in minutes) for terminating a Telnet-con-
nected session if no input is made. The factory default setting is 5 minutes.
SSH UI Idle
Displays the timeout settings (in seconds) terminating a SSH-connected session
if no input is made. The factory default setting is 5 minutes.
Idle
Displays the time to want for response to SSH authentication.
The factory default setting is 120 seconds.
Retries Time
Displays the number of times of retransmission of SSH authentication.
The factory default setting is 5.
SNMP Agent Sta-
Displays the SNMP access settings. "Disabled" is the factory default setting.
tus
Enable
Disable
Telnet Server Sta-
Displays the Telnet access settings. "Enable" is the factory default setting.
tus
Enable
Disable
Web Server Status Displays the Web access settings. "Disable" is the factory default setting.
Enable
Disable
Figure 3-12 System Security
Access is enabled.
Access is disabled.
Access is enabled.
Access is disabled.
Access is enabled.
Access is disabled.