Pos: 64 /Serie 750 (WAGO I/O SYSTEM)/Prozessabbild Lokalbus/AI/Prozessabbild 750-0495/040-010 Teil 2 @ 35\mod_1561047025168_21.docx @ 548654 @ 2332 @ 1
5.5
Measured Value Collections
The PI data type is either an unsigned (UInt32) or a signed (Int32) 32-bit
measured value. The value that is largest in the positive direction is declared as
an INVALID value and is returned when reading out the measured values marked
with "-" in the table "Measured Values" in section "Measured Values Overview."
Table 23: PI Data Type – Definition
Data Type
PI Uint32
PI Int32
5.5.1
Collection 010 – AC Measured Values

Table 24: Measured Values of Collection 010 in the Process Image

MET_ID Measured Value
Voltage
004
005
006
043
044
045
046
047
048
031
032
033
049
050
051
091
092
093
Manual
Version 1.0.0
Value Range
0 to 4,294,967,294
−2,147,483,648 to 2,147,483,646
RMS voltage, L1-N
RMS voltage, L2-N
RMS voltage, L3-N
Max. RMS voltage, L1-N
Max. RMS voltage, L2-N
Max. RMS voltage, L3-N
Min. RMS voltage, L1-N
Min. RMS voltage, L2-N
Min. RMS voltage, L3-N
RMS voltage, L1-L2
RMS voltage, L1-L3
RMS voltage, L2-L3
Arithmetic mean, voltage, L1-N
Arithmetic mean, voltage, L2-N
Arithmetic mean, voltage, L3-N
Peak value, voltage, L1-N
Peak value, voltage, L2-N
Peak value, voltage, L3-N
WAGO I/O System 750 XTR
750-495/040-010 3-Phase POM 20KV 300A XTR
PI Data Type
UInt32
UInt32
UInt32
UInt32
UInt32
UInt32
UInt32
UInt32
UInt32
UInt32
UInt32
UInt32
UInt32
UInt32
UInt32
UInt32
UInt32
UInt32
INVALID Value
4,294,967,295
2,147,483,647
PI Scaling
Factor
0.01 V
0.01 V
0.01 V
0.01 V
0.01 V
0.01 V
0.01 V
0.01 V
0.01 V
0.01 V
0.01 V
0.01 V
0.01 V
0.01 V
0.01 V
0.01 V
0.01 V
0.01 V