Installation
Legend
}
Gate's swing radius: Min. 800 mm
}
Cross section of gate profile: Max. 60 mm
}
Distance between safety switch and actuator: 5 mm + max. 1 mm
}
Installation is possible on left and right-hinged sliding gates within the protected and non-
protected area.
}
Installation height of handle: 1.05 m ± 0.1 m
}
Use an actuator for the respective cable outlet on the safety switch.
– Upward cable outlet: PSEN ml up l/r x.x
– Downward cable outlet: PSEN ml down l/r x.x
8.3.2
Install actuator on swing gate
Note that washers must be used when fastening M8 screws.
Actuator installed on mounting plate:
Drill holes (for M8 screws) in the mounting surface to secure the PSEN ml DHM mounting
plate (see
Operating Manual PSEN ml b 1.1/2.1/2.2, PSEN ml DHM
1005444-EN-02
[3]
[1] Swing gate with installed actuators
[2] Vertical panel with installed safety switch
[3] Gate's swing radius
Dimensions [
50]).
[2]
[1]
| 35