Wiring

5
Wiring
5.1

Important information

}
Hand-tighten the connector.
}
Information given in the
}
Note the max. cable length when operating with Safety Device Diagnostics.
Supply voltage on the safety control sys-
tem
≥ 20.4 V
≥ 24 V
≥ 28.8 V
5.2

Pin assignment, connector and cable

PIN
1
2
3
4
5
6
7
8
5.3

EMC requirements

}
Ensure the wiring and EMC requirements of EN 60204-1 are met.
Operating Manual PSEN ml b 1.1/2.1/2.2, PSEN ml DHM
1005444-EN-02
Technical details [
NOTICE
The colour marking for the connection lead only applies for the cable that
Pilz supplies as an accessory
Function
Operation of solenoid to open
and close guard locking (chan-
nel 2)
+24 V UB
Safety output channel 1
Safety output channel 2
Signal output/diagnostic output Y32
Operation of solenoid to open
and close guard locking (chan-
nel 1)
0 V UB
Diagnostics input
52]
must be followed.
Max. cable length
50 m
120 m
180 m
8-pin M12 connector
Terminal designation
S41
A1
12
22
S31
A2
Y1
Cable colour (Pilz
cable)
white
Brown
Green
Yellow
grey
Pink
Blue
Red
| 24