Install Fixing Screws Side-On To Actuator; Actuator Installation; Important Information - Pilz PSEN ml b 1.1 Operating Manual

Hide thumbs Also See for PSEN ml b 1.1:
Table of Contents

Advertisement

Installation
8.2.4

Install fixing screws side-on to actuator

Use four M5 screws to fix the safety switch to the mounting surface.
Legend
[1] Safety switch
[2] Actuator
[3] Fixing screws of the safety switch crosswise to the respective actuator
8.3

Actuator installation

8.3.1

Important information

}
The escape release handle must be clearly visible and must not be concealed.
}
The PSEN ml with DHM can be installed on left and right-hinged swing gates within the
protected and non-protected area.
For correct installation it's essential to comply with the distances shown in the diagram.
Operating Manual PSEN ml b 1.1/2.1/2.2, PSEN ml DHM
1005444-EN-02
[1]
WARNING!
Risk of injury due to loss of the safety function.
If the actuator PSEN ml DHM is installed incorrectly, the escape release
handle may be accessible from the outside. This may mean that the guard
locking is unlocked from the outside and the safety gate is opened, although
the hazardous machine is switched on.
– The actuator should be installed so that the escape release handle is
only accessible from inside the danger zone.
[2]
[3]
PSEN ml DHM
| 34

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents