Recommissioning - Pilz PSEN ml b 1.1 Operating Manual

Hide thumbs Also See for PSEN ml b 1.1:
Table of Contents

Advertisement

Function description
Mode of operation
In the danger zone, if the button of the escape release pin is pressed towards the safety
gate, the escape release impacts directly on the auxiliary release of the safety switch and
the auxiliary release unlocks the safety gate. The safety gate can be opened immediately,
enabling the operator to leave the danger zone.
There is a low signal at safety outputs 12 and 22 if the escape release was operated.
4.9.1

Recommissioning

1. Pull back the button of the escape release pin.
2. Switch the voltage off and then on again.
3. Carry out a function test using the escape release. The safety function may only be
checked by qualified personnel.
Operating Manual PSEN ml b 1.1/2.1/2.2, PSEN ml DHM
1005444-EN-02
INFORMATION
If guard locking is deactivated using the auxiliary release, there is a low sig-
nal at safety outputs 12 and 22. An error code will be issued (see under
Operation [
44]) and the safety switch switches to a fault condition.