Discharge records
This option shows the total number of discharge.
Heater
The Heater menu is used to set heating time and heating mode, as shown in Figure 4.18. Heater
mode includes two kinds, automatic mode and manual mode. In automatic mode, after the heater
the heat shrink tubing loaded and the cover closed, the program begins heating automatically. In
manual mode, users need to press the key "HEAT" to begin heating after the heater cover closed.
Heat time needs to set by users according to specific heat shrinkable. Select this option "Heat Time",
and press the key or to change the time. Select the option "Auto Heat", and press the key or
to change the mode. When the option "Auto Heat" is OFF, user needs to press the key "Heat" to start
heating.
Electrodes
TElectrodes menu is used to view and calibrate the arc degree. The electrodes discharge arc without
motor pushing forward when the fiber is ready for fusion. The fiber is burned into the shape of arc,
and the shortest distance of the shape of arc reflects the electrodes arc degree. In general, the
shortest distance 9mm to 12mm (Standard distance) will get loss less than 0.02db.
OPERATION MANUAL OUTDOOR MULTIFUNCTION FUSION SPLICER FUSION SPLICER 5.7
FIGURE 4.18
FIGURE 4.19
25