Discharge records
This option shows the total number of discharge.

Heater

The Heater menu is used to set heating time and heating mode, as shown in Figure 4.18. Heater 
mode includes two kinds, automatic mode and manual mode. In automatic mode, after the heater 
the heat shrink tubing loaded and the cover closed, the program begins heating automatically. In 
manual mode, users need to press the key "HEAT" to begin heating after the heater cover closed. 
Heat time needs to set by users according to specific heat shrinkable. Select this option "Heat Time", 
and press the key      or      to change the time. Select the option "Auto Heat", and press the key     or  
to change the mode. When the option "Auto Heat" is OFF, user needs to press the key "Heat" to start 
heating.

Electrodes

TElectrodes menu is used to view and calibrate the arc degree. The electrodes discharge arc without 
motor pushing forward when the fiber is ready for fusion. The fiber is burned into the shape of arc, 
and the shortest distance of the shape of arc reflects the electrodes arc degree. In general, the 
shortest distance 9mm to 12mm (Standard distance) will get loss less than 0.02db.