Fiber Clamping - Artic FUSION SPLICER 5.7 Operation Manual

Outdoor multifunction fusion splicer
Table of Contents

Advertisement

Fiber clamping
Open the windproof cover and the two side fiber platens, then, put the prepared fiber into 
PICTURE 16
V-groove through the locating slot. Make sure that the fiber end face should be located  
between the V-groove edge and two electrodes. 
Shown in Figure 3.5
FIGURE 3.5
Please operate carefully and donʼt let the fiber end face touch any other object. Then close 
the large platen to fix optical fiber, which should be placed horizontally in the V-groove, 
without upturned phenomenon. If clamping failed, you can lift fiber carefully and repeat the 
operation above until the fiber clamping is qualified. 
Similarly, prepare and clamp the other optical fiber. 
Then, close the windproof and continue to observe the amplified fiber from the display. If the 
fiber end face is uneven, tilt or damaged, you need to remove the fiber to cut again.