3. Don't attempt to disassemble the machine or its accessories, only authorized agencies can repair it. 4. Please don't touch electrodes during working time, or it may cause personal injury. 5. When liquid or foreign body into the machine, or smoke, odor, noise, etc., or a strong impact, please immediately shut down the machine, and pull out the AC power. Note When using the machine, improper operation may cause damage to the machine or even danger for human health. It is suggested to operate in the following way. 1. This type of the machine is only used for splicing quartz glass fiber, not in place of any other matter. 2. Don't use or store the machine in a high temperature or humidity environment (otherwise it may damage the equipment or cause the machine performance degradation). 3. While using the machine in a dust environment, try to avoid dust as far as possible. 4. When moving the machine from low temperature to a high temperature, there should be any heating process to eliminate condensation. 5. Please use a high-purity anhydrous alcohol (purity>99%) to clean magnifying lens, reflector and fiber v-groove surface. 6. The splicing the machine must be handled gently to avoid strong vibration or impact, and with carrying case for transportation or storage. 7. Maintain the whole the machine once a year. Legal statement Without the written consent of our company, any unit or individual will not be allowed to extract or copy part of the contents of this manual, or transmitted in any form. Products described in this manual, including our company software, unless approved by the related oblige, otherwise no one can be in any form for the software to copy, distribute, modify, excerpts, decompiling, disassembling, decryption, reverse engineering, lease, transfer, sublicense and other ACTS of infringing the software copyright. Attention: The manual describes some features and functions of the product and its acces- sories, related to the production batch, therefore, the description in this manual may not exactly match the product you purchased, as well as its accessories. OPERATION MANUAL OUTDOOR MULTIFUNCTION FUSION SPLICER FUSION SPLICER 5.7...
Our Company reserves the right to modify any information in this manual at any time, without any prior notice and does not undertake any responsibility. Limitation of liability: Within the scope of applicable law, our company, in any case, donʼt compensate for any special, incidental, indirect, secondary damage due to using this manual or the product, and also donʼt compensate for any loss of profits, data, goodwill or anticipated savings. Within the scope of applicable law, in any case, our company will undertake the greatest responsibility for the losses suffered in the use of the product described in this manual in the limit of the price you paid for the product. (Except in cases involving personal injury according to applicable law for damages). Start to comprehend splicer Overview of splice FIGURE 2.1 Key appearance FIGURE 2.2 OPERATION MANUAL OUTDOOR MULTIFUNCTION FUSION SPLICER FUSION SPLICER 5.7...
Page 5
Table 1 Power 2 Enter 3 Menu / Exit 4 Up 5 Left 6 Down 7 Right 8 Heat 9 Arc 10 Reset 11 Switch Video 12 Auto Splice Key functions Table While Power On, press this key to shut down. While Power OFF, press this key to Power On. Under the standby interface, press this key to discharge a weak arc. In menu, press this key to enter the next submenu. If permitted, press this key to run. If permitted, press this key to switch between the left and right sides of CMOS Sensor, Motors and so on. Under the standby interface, press this key to enter the main menu. Under the main menu interface, press this key to return the upper menu. Under the standby interface, press this key to increase the LCD backlight. In the CMOS sensor step, press this key to increase the CMOS sensor backlight. In motor adjustment, press this key to drive up the fiber. If permitted, press this key to move up the cursor. OPERATION MANUAL OUTDOOR MULTIFUNCTION FUSION SPLICER FUSION SPLICER 5.7...
Page 6
Under the standby interface, press this key to gap the fiber. Under the main menu, press this key to select the left icon. In motor adjustment, press this key to drive the corresponding motor to move to the left. Under the standby interface, press this key to decrease the LCD backlight. In the setup of the CMOS sensor, press this key to decrease the CMOS sensor backlight. In function of a motor test, press this key to move down the corresponding motor. If permitted, press this key to move down the cursor. Under the standby interface, press this key to align the fiber. Under the main menu, press this key to select the right icon. In motor adjustment, press this key to drive the corresponding motor to move to the right. Under the standby interface, press this key to fuse. OPERATION MANUAL OUTDOOR MULTIFUNCTION FUSION SPLICER FUSION SPLICER 5.7...
Page 7
In the Power On state, press this key to reset the motor position. Under the standby interface, press this key to switch video mode. Under the standby interface, press this key to run auto splice. OPERATION MANUAL OUTDOOR MULTIFUNCTION FUSION SPLICER FUSION SPLICER 5.7...
Heating time 30 seconds(heat-shrinking tube width is 40mm or 60mm) Magnification 150 times/double show,300 times/single show Observation mode A high sensitivity CMOS sensor, Color LCD of 5.6 inch with pixels 640x480 Fusion Records Support to store 4000 groups of Fusion Records Estimate loss Supported Tension Supported,2N Operation Interface Battery capacity 10.8Ah;Typical 220 times fusion; Show remaining real-time Power supply Adapter : AC100-240V(50/60HZ); Output : DC11~13.5V Electrodes times 4000 times Interface Interface 12V DC power input,USB2.0 Operation Environment Altitude: 0-5000m; Humidity: 0-95%; Temp: -10℃- +50℃; Air speed: <=15m/s Volume/weight 160mm (L) ×150mm (W) ×145mm (H) /2.8kg(Battery Included) OPERATION MANUAL OUTDOOR MULTIFUNCTION FUSION SPLICER FUSION SPLICER 5.7...
Tools Configuration Carrying Case: Keep the splicer away from the bumping and compact Working platform. Fiber Cleaver: Cutting fiber Preparation of the fiber end face. Spare electrodes: Replace the aging electrodes. Strip clamp: Stripping the fiber coating. Alcohol pump bottle: Used to hold alcohol. Cooling tray: hold heat shrink tube to cool. AC-DC Adapter for splicer. INSTALLATION MANUAL FIBER ACCESS TERMINAL CLOSURE AR-DB16F...
A complete splice A full fiber splice procedure including: the fiber end face preparation, fiber splicing, tension test, heating and cooling of shrink tube. This chapter will introduce details of the specific process of the fiber splice. Power on FIGURE 3.1 Press and hold the power button until the power indicator light, then, LCD also enter the self-test screen. Preparation of fiber end face Prepare two optical fibers, as shown in Figure 3.2, in which an optical fiber is set into the heat shrink tube. FIGURE 3.2 OPERATION MANUAL OUTDOOR MULTIFUNCTION FUSION SPLICER FUSION SPLICER 5.7...
Page 11
As shown in Figure 3.3, clenched fiber cleaver, place the fiber into the tooth of the clamps by the left hand, reserve bare fiber 30 to 40 mm stripped fiber coating. Use a cotton ball dipped in anhydrous alcohol (purity>99%) wipe optical fiber coating layer that residual debris, Figure 3.4 shows. FIGURE 3.3 Put the cleaned fiber into the cutter positioned groove, the edge alignment of the fiber coating cutter ruler “13” scale outside (the scale is greater than 13, shown in Figure 3.4). Close small platen, requiring that the bare fiber straight on the left and right rubber on the chop- ping block. Together with close the large plate, and push the cutter blade slider to the other end to cut off the fiber. After Cutting, open the large platen to take away cutting broken fiber into the waste fiber storage box. (Broken fiber has a great harm to human health, so, please be sure to collect and chop broken fiber). Open the small platen, and carefully take out the cut end face fiber. Donʼt make the fiber cross section touching any other objects, to avoid damage or contamination end face. FIGURE 3.4 OPERATION MANUAL OUTDOOR MULTIFUNCTION FUSION SPLICER FUSION SPLICER 5.7...
Fiber clamping Open the windproof cover and the two side fiber platens, then, put the prepared fiber into PICTURE 16 V-groove through the locating slot. Make sure that the fiber end face should be located between the V-groove edge and two electrodes. Shown in Figure 3.5 FIGURE 3.5 Please operate carefully and donʼt let the fiber end face touch any other object. Then close the large platen to fix optical fiber, which should be placed horizontally in the V-groove, without upturned phenomenon. If clamping failed, you can lift fiber carefully and repeat the operation above until the fiber clamping is qualified. Similarly, prepare and clamp the other optical fiber. Then, close the windproof and continue to observe the amplified fiber from the display. If the fiber end face is uneven, tilt or damaged, you need to remove the fiber to cut again. OPERATION MANUAL OUTDOOR MULTIFUNCTION FUSION SPLICER FUSION SPLICER 5.7...
Optical fiber fusion After clamping, the machine is in a ready state, as shown below. If in "Automatic" splice mode, PICTURE 16 auto splice begins as soon as the windproof closed. If in "Manual" splice mode, the user must press the "SET" button to run the splice routine. FIGURE 3.6 First, select the fusion parameter group according to the optical fiber type. Press “MENU” to enter the main menu, and then select the “parameters” icon and press the “confirm” key to enter the menu. We need to select a fusion parameter group matched with splice fiber type. It is suggested to choose SM8. Press "SET" to start the splicing procedure. The machine drives the motor, which will promote both sides of fibers to the middle of the screen, judging the fiber end face whether meet the requirements. If qualified, turn to the next process, otherwise show a tip of bad end face and stop. After judgment, the alignment motor will adjust fiber Position to make both sides of fibers align in three-dimensional. At last, the electrode discharge arc to fuse fiber. When fusion is completed, the machine will give the loss estimates, and have a tension test if needed. Heat-shrinkable The optical fiber fusion point is really fragile and easily broken, so, you need protection by using heat shrinkable. Open the windproof cover, large platen and heater cover. Gently remove fiber, and donʼt bend fiber greatly to avoid the fusion point broken. OPERATION MANUAL OUTDOOR MULTIFUNCTION FUSION SPLICER FUSION SPLICER 5.7...
Move heat shrinkable tubing to the fusion point, which must be in the middle. Then, place heat shrinkable tubing in the middle of the heating furnace. The heater begins heating as soon as heating furnace closed. About 34 seconds later, heating shrinking has been completed. The figure below is the heat shrink tubing before thermal shrinkage and after PICTURE 16 thermal shrinkage. FIGURE 3.7 Cooling The heat shrinkable tubing after heating at in a high temperature, and need cooling. Hang the cooling tray on the carrying handle. So, after heating, pull out the fiber from the heating furnace to the cooling tray by hands. About 1 minute later, it cools to the ordinary temperature. Menu instruction The machine adopts METRO-style menu, whose interface is simple, beautiful and convenience for operation. The operation interface has 8 icons, and each icon corresponds to a different functional menu. FIGURE 4.1 FIGURE 4.1 OPERATION MANUAL OUTDOOR MULTIFUNCTION FUSION SPLICER FUSION SPLICER 5.7...
For the main menu interface : In the standby state, press the key to enter interface of main menu. In the main menu, press the key to exit the main menu to the standby interface. PICTURE 16 In the main menu, press the direction keys, and the corresponding direction on the next icon is selected. Press the key to enter the submenu. In submenu: Press the key or to select the up down cursor. Press the key or to modify the current data. Press the key to enter the next submenu. Press the key to enter the upper menu. Parameter setting menu FIGURE 4.2 Fusion Mode "Parameters" menu is used to select and set the fiber splicing parameters. Menu forms by different splicing parameters submenu, as shown in Figure 4.2. Each sub-menu is a group of splicing parameters, and the menu is composed by the part of the number, file name, pattern and state. The number from 0 to 39, a total of 40 groups of parameters can be used. Mode Auto, Calibrate, Normal three kinds, of which the Auto class of parameters derived experimental optimization for the factory and cannot be modified and recommended for new users. The data of the Calibrate parameters can be modified except the pre-discharge and post-discharge time. All the Normal parameters can be modified. OPERATION MANUAL OUTDOOR MULTIFUNCTION FUSION SPLICER FUSION SPLICER 5.7...
Page 16
PICTURE 16 FIGURE 4.3 The “type” represent which the fiber is fused by the parameter. Abbreviations are explained in the following. SM: Single mode fiber MM: Multi mode fiber DS: Dispersion shifted fiber NZDS: Non-zero dispersion-shifted fiber The state ON/OFF says the group is currently used or not. Press the key or to change the current splicing parameter group. Press the key to enter the para group, as shown above. The parameter consists of the following parameters: Prefuse time In the total fusion process, a short time about 30ms in SM 16ms in MM, . It is not recommended for the new user to modify. Fuse time In the total fusion process, a long time 2.0 seconds in SM, 1.2 seconds in MM. It is not recommended for the new user to modify. Arc Discharge current means that the discharge arc current intensity. The high value of the current corresponds to a greater arc, resulting in a higher temperature. The fiber is ablated more seriously. Press the key or to increase or decrease the parameter value. Pushing Overlap The pushing forward distance in fusion process. Press the key or to add or sub the value of overlap. Gapping The distance of fiber gap before fusing. Press the key or to change it. Max end face The angle between the fiber end and vertical direction is the end face. In the process of judging the fiber end face, the fiber end face should not more than the Max end face. State It shows them using state of the current viewing parameter group. You can press the key or to change the parameter. OPERATION MANUAL OUTDOOR MULTIFUNCTION FUSION SPLICER FUSION SPLICER 5.7...
Setup The “setup” menu is used to set the data including the Brightness, Auto power off, Tension, Language etc., as shown below. PICTURE 16 PICTURE 16 FIGURE 4.4 FIGURE 4.4 Operation Mode The operation mode is the method of the machine fusion, which consists of: automatic or manual mode. This parameter, automatically, turns off the windshield in the standby interface, the splicing machine will begin running splice fiber optic procedures. Manual mode requires the user to press the "SET" button, and the machine will begin splicing optical fiber. Select the menu button, and press the key the parameter values w ill switch between "automatic" and "manual". Suspend 1 When fiber splicing, fiber advancing to meet the gap conditions, the program pauses, waiting for the further operation of the user. For continue to splicing, press "SET" button. To interrupt splicing, press the "RESET" button. Suspend 2 Fiber suspend the running at the end of the subsequent process of aligning. Reset time After a fiber splicing, to prepare for the next splice, propulsion motors need to be reset to the reference position. Fiber splicing completed, open the windscreen, over sometime to wait for propulsion motors to begin to reset. The waiting is the time that automatically reset. The menu selected, press the key or to change the parameter values. OPERATION MANUAL OUTDOOR MULTIFUNCTION FUSION SPLICER FUSION SPLICER 5.7...
Page 18
FIGURE 4.5 FIGURE 4.5 Language Language shows the display language current software used. There are two languages available : Chinese The software interface displays Chinese. English The software interface displays English. FIGURE 4.6 OPERATION MANUAL OUTDOOR MULTIFUNCTION FUSION SPLICER FUSION SPLICER 5.7...
Camera brightness Press the key to enter the interface of camera brightness, as shown below Press the key or to modify the gain of CMOS camera resulting in the change of camera brightness. Press the key to switch the CMOS camera sensor between X and Y. FIGURE 4.7 Tension Open the option, splice completed, the machine would impose 2 Newtonʼs pulling on the fiber to test the quality of splicing. If the fiber broke, it means the fusion failed. Press the key to switch the tension state between ON and OFF. Auto shutdown When the option is turned on, the machine will shut down automatically if no operation within ten minutes. Function The function menu lists the splicing the machine with some features, such as time and date, motor test, export splicing records, program upgrade, etc. as shown in Figure 4.8. OPERATION MANUAL OUTDOOR MULTIFUNCTION FUSION SPLICER FUSION SPLICER 5.7...
Page 20
FIGURE 4.8 Date And Time Press the key to enter the interface of Date and Time as shown in figure 4.9. Press the key or to move the selection cursor, and then press the key or to modify the selection value FIGURE 4.9 OPERATION MANUAL OUTDOOR MULTIFUNCTION FUSION SPLICER FUSION SPLICER 5.7...
Page 21
Motor Test Motor test imitates the distance of the push motor moving forward in the fusion process. Press the key to enter the interface. After the prepared fiber clamped into the machine, you must press the key to run the test. The test results will be given at the end of the test, as shown in Figure 4.10, which shows the distance of each push motor moving forward. Export Records The option is used to export the fusion records memories in the machine. After the U disk inserted into the USB port, choose this option and press the key to confirm fusion records export. The program begins to test the USB port and then find the records. If thereʼs no record, program will prompt error. FIGURE 4.11 OPERATION MANUAL OUTDOOR MULTIFUNCTION FUSION SPLICER FUSION SPLICER 5.7...
Software upgrade This function is used to upgrade software in the machine. After the U disk with upgrade file inserted into USB port, choose this option and press the key to upgrade. As shown in Figure 4.12, program begins upgrading. Attention that after upgraded, users need to boot. FIGURE 4.12 Maintenance The Maintenance menu consists of Electrodes Aging, Motor Checking, Fusion Records, Arc Numbers, etc, as shown in Figure 4.13. FIGURE 4.13 OPERATION MANUAL OUTDOOR MULTIFUNCTION FUSION SPLICER FUSION SPLICER 5.7...
Page 23
Electrodes aging New electrode discharge instability and the need for the discharge of a certain number of times to stabilize the arc which called electrode aging. When electrode replaced, enter this menu and then press the key to start aging the electrode, as shown in Figure 4.14. Donʼt open windproof cover in aging process. FIGURE 4.14 Motor checking Motor checking is used to check the motor performance and change the motor position. Total of 4 motors are available for operation. OPERATION MANUAL OUTDOOR MULTIFUNCTION FUSION SPLICER FUSION SPLICER 5.7...
Page 24
Press the key to enter the video interface. Press the key to switch the left and right motors. The align motor will move up or down by pressing the key or . The push motor will drive left or right by pressing the key or Fusion Records FIGURE 4.16 This option stores working parameters, fiber end face, the environment and date in each splicing. The machine can store 4000 groups of fusion records. The key can be pressed to enter the page of fusion record, and the page displays ten groups of fusion records, sequence from top to bottom by the latest fusion time as shown above. Press the key or to the contiguous page. Press the key to enter the page of fusion records. FIGURE 4.17 OPERATION MANUAL OUTDOOR MULTIFUNCTION FUSION SPLICER FUSION SPLICER 5.7...
Discharge records This option shows the total number of discharge. Heater The Heater menu is used to set heating time and heating mode, as shown in Figure 4.18. Heater mode includes two kinds, automatic mode and manual mode. In automatic mode, after the heater the heat shrink tubing loaded and the cover closed, the program begins heating automatically. In manual mode, users need to press the key “HEAT” to begin heating after the heater cover closed. Heat time needs to set by users according to specific heat shrinkable. Select this option “Heat Time”, and press the key or to change the time. Select the option “Auto Heat”, and press the key or to change the mode. When the option “Auto Heat” is OFF, user needs to press the key “Heat” to start heating. FIGURE 4.18 Electrodes TElectrodes menu is used to view and calibrate the arc degree. The electrodes discharge arc without motor pushing forward when the fiber is ready for fusion. The fiber is burned into the shape of arc, and the shortest distance of the shape of arc reflects the electrodes arc degree. In general, the shortest distance 9mm to 12mm (Standard distance) will get loss less than 0.02db. FIGURE 4.19 OPERATION MANUAL OUTDOOR MULTIFUNCTION FUSION SPLICER FUSION SPLICER 5.7...
Page 26
Arc Adjust Select this option into the video interface, as shown in Figure 4.20. Cut and clamp fiber according to splice procedure, and then press the key . The calibration program starts to run and test results are given. According to the test results, manually set the splicing parameters of discharge current, and repeat the above steps until the test results meet the requirements. FIGURE 4.20 Arc calibrate Automatic calibration can automatically change the fusion parameters in the discharge current until the test results meet the requirements on the basis of test results. The test interface is shown in Figure 4.21. FIGURE 4.21 OPERATION MANUAL OUTDOOR MULTIFUNCTION FUSION SPLICER FUSION SPLICER 5.7...
Status Status menu gives the atmospheric pressure, the internal temperature, the ambient temperature and the remaining power, as shown in Figure 4.22. FIGURE 4.22 Information In Information menu, users can inquiry the serial number of the machine and software version information, as shown in Figure 4.23 below. FIGURE 4.23 OPERATION MANUAL OUTDOOR MULTIFUNCTION FUSION SPLICER FUSION SPLICER 5.7...
Routine maintenance Cleaning Cleaning V groove V-groove is a V slot on the ceramic substrate of narrow width, easily to accumulate dust which will make the fiber move instability and cause a bad fusion, therefore, the V groove should be cleaned regularly. The following is the way of cleaning the V groove: 1. Place the fiber with good enface into the V groove to remove the pollution, shown in figure 5.1. FIGURE 5.1 2. Use a cotton swab soaked with alcohol to clean the surface and bottom of the V groove. At last, the alcohol should be the natural air-dry or wiped dry by the dry cotton swab. Shown in figure 5.2. FIGURE 5.2 OPERATION MANUAL OUTDOOR MULTIFUNCTION FUSION SPLICER FUSION SPLICER 5.7...
Page 29
Cleaning fiber presser foot The dust accumulated on the fiber press foot will cause pressure instability and affect the quality of fusion. So, it should be wiped off from the fiber pressure foot regularly. Open the windproof cover, and then use the cotton dipped in alcohol to clean the surface of the presser foot. When cleaning, donʼt repeat back and forth with cotton, but to wipe the foot in one direction. Besides, users need to spin the cotton swabs, keeping the unused cotton facing the presser foot, waiting for the alcohol volatile. Cleaning reflector FIGURE 5.3 When the reflector accumulated with dust, the fiber imaging through the reflector will fuzzy and in incorrect position as a result of bad fusion loss, so the dust should be wiped off from the reflector regularly. When cleaning, with reference of the below graphic, from the center to the edge of the reflector, user should rotate the cotton ball dipped in alcohol to clear repeatedly until the reflector is of neat and tidy. Cleaning objective lens Microscope is the core component of the machine optical system. So its surface must be kept clean, and users should regularly clean. The microscope is cleaned by the swab which dipped in a little alcohol, with a spiral movement from the center to the edge of the lens and the rotation around the swab until to spin out the edge of the lens. OPERATION MANUAL OUTDOOR MULTIFUNCTION FUSION SPLICER FUSION SPLICER 5.7...
FIGURE 5.4 Replacing electrode Arc produces by high temperature, melting the fiber, which will produce silicon oxide vapour and some deposited on the electrodes, causing the arc instability. Therefore, users are recommended to replace electrodes when discharge reached 2500 times. Please replace the electrodes according to the following steps: 1.) Shut down the power. 2.) Loosen setscrews of electrodes cover and remove the electrodes cover, as shown in Figure 5.5 3.) Take out the electrode from the electrode holder. (Electrode is fixed on the electrode holder, figure 5.6). FIGURE 5.5 FIGURE 5.6 With tissue paper dipped in alcohol to clean the new electrodes, then, install the electrodes into the original electrodes seat position. Close the electrodes cover and tighten the screws. Close the windproof cover and power on the machine. Take an electrode aging. Run 3 times fiber fusion if current fusion parameter is Auto mode otherwise run Arc Test or Arc Calibrate if current fusion parameter is normal or calibrate. Note: The replacement of the electrodes should be gentle, so as not to damage the machine or stabbed himself. OPERATION MANUAL OUTDOOR MULTIFUNCTION FUSION SPLICER FUSION SPLICER 5.7...
Clean or replace the electrodes The electrodes are of dirty or damaged; Or Electrodes do not discharge the high-voltage board is fault. Recut fiber or clean the V groove, or increase The end face of fiber is bad, or the fiber is Tip of “Please check L(R) end face” the max endface value of fusion para. polluted, or the image is unclear. The motor exceeds the range of operation Reload the fiber in correct position when Tip of “Resetting push motors” reset to the original Position resetting completed. Operate when cover closed. The cover is opened Tip of “Please close cover” Check the mirror ,lens or the image light Display lamp does not light or some other Tip of “X(Y) Image Light Error” reasons The fiber is not completely loaded into the V Tip of “(L,R)Fiber On Error position!” Reload fiber or recut fiber. groove or fiber is dirty The gap of fiber is un-fittable. Tip of “Please Gap Again!” Take a gap process first. Note: If the above-mentioned problems still exist after handling, please contact technical support. OPERATION MANUAL OUTDOOR MULTIFUNCTION FUSION SPLICER FUSION SPLICER 5.7...
Page 32
Appendix A Warranty terms and conditions If the machine fault occurs on the date of delivery in a year, it will get a free repair. But if the following occurs, it is not in the warranty scope: ★ Failure or damage caused by natural disasters. ★ Failure or damage caused by abnormal voltage power supply. ★ Failure or damage caused by wrong operation. ★ Failure or damage caused by the operation not according to the userʼs manual. ★ Loss unit (such as electrodes). Before sending the machine, please contact with the manufacturer or agent. Required information of repair (Please contain the following information in machine) <1> Your full name, your company, address, telephone number, fax number and e-mail address <2>Type of the machine and the serial number. <3> The problems encountered. When and under what conditions the problem happened. Now how the condition of the machine. Information of screen display and the error tips etc. OPERATION MANUAL OUTDOOR MULTIFUNCTION FUSION SPLICER FUSION SPLICER 5.7...