For the main menu interface :
In the standby state, press the key to enter interface of main menu.
In the main menu, press the key to exit the main menu to the standby interface.
PICTURE 16
In the main menu, press the direction keys, and the corresponding direction on the next icon
is selected.
Press the key to enter the submenu.
In submenu:
Press the key or to select the up down cursor.
Press the key or to modify the current data.
Press the key to enter the next submenu.
Press the key to enter the upper menu.
Parameter setting menu
FIGURE 4.2
Fusion Mode
"Parameters" menu is used to select and set the fiber splicing parameters. Menu forms by
different splicing parameters submenu, as shown in Figure 4.2. Each sub-menu is a group of
splicing parameters, and the menu is composed by the part of the number, file name, pattern
and state. The number from 0 to 39, a total of 40 groups of parameters can be used. Mode
Auto, Calibrate, Normal three kinds, of which the Auto class of parameters derived
experimental optimization for the factory and cannot be modified and recommended for
new users. The data of the Calibrate parameters can be modified except the pre-discharge
and post-discharge time. All the Normal parameters can be modified.
15
OPERATION MANUAL OUTDOOR MULTIFUNCTION FUSION SPLICER FUSION SPLICER 5.7