Arc Adjust
Select this option into the video interface, as shown in Figure 4.20. Cut and clamp fiber according to 
splice procedure, and then press the key     . The calibration program starts to run and test results are 
given. According to the test results, manually set the splicing parameters of discharge current, and 
repeat the above steps until the test results meet the requirements.
Arc calibrate 
Automatic calibration can automatically change the fusion parameters in the discharge current until 
the test results meet the requirements on the basis of test results. 
The test interface is shown in Figure 4.21.
OPERATION MANUAL OUTDOOR MULTIFUNCTION FUSION SPLICER FUSION SPLICER 5.7
FIGURE 4.20
FIGURE 4.21