Function tests
8
4.3-14 Do a test of the secondary guarding
electrical (SGE)
1. Press the sensor bar
and then release it.
Result: The audible/visual alarm goes on
while the bar is pressed and goes off after it
is released. The reset button illuminates when
the bar is pressed, and goes off when the bar
is released.
2. Press the sensor bar for more than 1 second
and then release it.
Result: The audible/visual alarm goes on
immediately and stays on after the bar is
released. The reset button illuminates.
3. Press the reset
8
Result: The audible/visual alarm and reset
button light go off.
4. Start the engine.
5. Press the sensor bar for less than 1 second and
then release it.
Result: The audible/visual alarm goes on
while the bar is pressed and goes off after it
is released. The reset button illuminates when
the bar is pressed, and goes off when the bar
is released.
6. Press the sensor bar for more than 1 second
and then release it.
Result: The audible/visual alarm goes on
immediately and stays on after the bar is
released. The engine stops after 1 second.
The reset button illuminates.
SJ82 T, SJ86 T
TM
1
3
=
STOP
2
+
+
4
for less than 1 second
7
button.
Section 4 – Inspections Before Operation
7. Press the reset button.
Result: The audible/visual alarm and reset
button light go off.
8. Start the engine.
9. Operate a drive function in the high torque
mode.
10. Press the sensor bar for less than 1 second and
then release it.
Result: The function will stop while the bar is
pressed and the function will continue when
the bar is released. The audible/visual alarm
goes on while the bar is pressed and goes off
after it is released. The reset button illuminates
when the bar is pressed, and goes off when
the bar is released.
11. Press the sensor bar for more than 1 second
and then release.
Result: The function will stop and the audible/
visual alarm goes on immediately and stays
on after the bar is released. The engine stops
after 1 second. The reset button illuminates.
12. Start the engine.
13. Operate a platform function (i.e., lift, extend, or
rotate).
7
213205AAA