Interactive Fire Alarm System
Release 3
Installation Handbook
Fire Alarm Control Panel, BS-310/320
Controller, BC-320
Protecting life, environment and property...
116-P-ASAFE-FA/DE, Rev. J, 2011-12-06

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the AUTRO SAFE Self Verify BS-310 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Autronica AUTRO SAFE Self Verify BS-310

  • Page 1 All manuals and user guides at all-guides.com Interactive Fire Alarm System Release 3 Installation Handbook Fire Alarm Control Panel, BS-310/320 Controller, BC-320 Protecting life, environment and property... 116-P-ASAFE-FA/DE, Rev. J, 2011-12-06...
  • Page 2 This publication, or parts thereof, may not be reproduced in any form, by any method, for any purpose. Autronica Fire and Security AS and its subsidaries assume no reponsibility for any errors that may appear in the publication, or for damages arising from the information in it.
  • Page 3: Table Of Contents

    2.5.2 Connecting the Batteries to Connection Module and   Power Supply ................27     Connecting the Network Cables (AUTROLON) ........ 29 Installation Handbook, AutroSafe Interactive Fire Alarm System, Release 3, 116-P-ASAFE-FA/DE, Rev. J, 2011-12-06, Autronica Fire and Security AS...
  • Page 4 Service and Maintenance ..........57         Introduction ..................57     Monthly Maintenance ................ 57     Annual Service and Maintenance ............. 57 Installation Handbook, AutroSafe Interactive Fire Alarm System, Release 3, 116-P-ASAFE-FA/DE, Rev. J, 2011-12-06, Autronica Fire and Security AS...
  • Page 5 All manuals and user guides at all-guides.com Reader’s Comments ............61     Installation Handbook, AutroSafe Interactive Fire Alarm System, Release 3, 116-P-ASAFE-FA/DE, Rev. J, 2011-12-06, Autronica Fire and Security AS...
  • Page 6: Introduction

    1.2 The Reader The handbook is intended to be used by Autronica Fire and Security trained service and technical personnel who are responsible for the installation of the AutroSafe Interactive Fire Alarm System.
  • Page 7: Reference Documentation

    All manuals and user guides at all-guides.com Introduction 1.3 Reference Documentation In addition to this handbook, Autronica Fire and Security offers the following documentation: Handbook Item Number System Specification P-ASAFE/XE Installation Handbook, Fire Alarm Control Panel (BS-310/320) / Controller (BC-320)
  • Page 8: Environmental Requirements

    Modules, I/O modules and power supply only. The cabinet is thus delivered with a black panel in front instead of the Operator Front Panel. Installation Handbook, AutroSafe Interactive Fire Alarm System, Release 3, 116-P-ASAFE-FA/DE, Rev. J, 2011-12-06, Autronica Fire and Security AS...
  • Page 9: Assembly Drawing

    Module BSL-310 Power Module Operator Board BSS-310A/02 BSZ-310 Power Supply BSS-103/01 Battery Cover Printer BUP-310 Battery Shelf (Not included in Controller, BC-320) Installation Handbook, AutroSafe Interactive Fire Alarm System, Release 3, 116-P-ASAFE-FA/DE, Rev. J, 2011-12-06, Autronica Fire and Security AS...
  • Page 10: Mounting

    A crosshead screwdriver can be used for this purpose. Installation Handbook, AutroSafe Interactive Fire Alarm System, Release 3, 116-P-ASAFE-FA/DE, Rev. J, 2011-12-06, Autronica Fire and Security AS...
  • Page 11: Cabinet Dimensions

    Mounting 1.10 Cabinet Dimensions The cabinet (Fire Alarm Control Panel / Controller) has the following dimensions: (cabinet) (front) (cabinet) (front) (Ref. BS-1109) Installation Handbook, AutroSafe Interactive Fire Alarm System, Release 3, 116-P-ASAFE-FA/DE, Rev. J, 2011-12-06, Autronica Fire and Security AS...
  • Page 12: Surface Mounting

     Unscrew the 2 screws on the top and the bottom on the right hand side of the front panel. Lock screw Lock screw  Open the front panel. Installation Handbook, AutroSafe Interactive Fire Alarm System, Release 3, 116-P-ASAFE-FA/DE, Rev. J, 2011-12-06, Autronica Fire and Security AS...
  • Page 13  Unscrew the 4 wing nuts on the right and left hand side of the cabinet, then close the front panel, and remove the front panel from the cabinet . Front Panel wing nuts Installation Handbook, AutroSafe Interactive Fire Alarm System, Release 3, 116-P-ASAFE-FA/DE, Rev. J, 2011-12-06, Autronica Fire and Security AS...
  • Page 14: Mounting The Cabinet

     Partly fasten the upper screws.  Hang the cabinet onto the upper screws.  Partly fasten the bottom screws.  Tighten all screws. Installation Handbook, AutroSafe Interactive Fire Alarm System, Release 3, 116-P-ASAFE-FA/DE, Rev. J, 2011-12-06, Autronica Fire and Security AS...
  • Page 15: C Able Inlets / Outlets

     Make sure that the cables are fastened properly. 1.11.4 Cable Connections For detailed information on cable connections, refer to chapter 3 in this handbook. Installation Handbook, AutroSafe Interactive Fire Alarm System, Release 3, 116-P-ASAFE-FA/DE, Rev. J, 2011-12-06, Autronica Fire and Security AS...
  • Page 16: Mounting The Batteries

     Close the front panel, and tighten the two lock screws on the top Batteries; and the bottom on the right hand side. 2x12V / 12Ah Installation Handbook, AutroSafe Interactive Fire Alarm System, Release 3, 116-P-ASAFE-FA/DE, Rev. J, 2011-12-06, Autronica Fire and Security AS...
  • Page 17 All manuals and user guides at all-guides.com Mounting Wing nuts Ribbon cable connection Lock screw (front door) Lock screw Installation Handbook, AutroSafe Interactive Fire Alarm System, Release 3, 116-P-ASAFE-FA/DE, Rev. J, 2011-12-06, Autronica Fire and Security AS...
  • Page 18: Flush Mounting In A Wall

     Unscrew the 5 screws on the mounting plate inside the cabinet and carefully lift it out of the cabinet. Mounting screws Installation Handbook, AutroSafe Interactive Fire Alarm System, Release 3, 116-P-ASAFE-FA/DE, Rev. J, 2011-12-06, Autronica Fire and Security AS...
  • Page 19: Flush Mounting Before Construction Of The Wall

    - without the inside units and front panel - can be used as a casting frame. WARNING: To avoid deformation, make sure that the cabinet is supported inside before concreting. Installation Handbook, AutroSafe Interactive Fire Alarm System, Release 3, 116-P-ASAFE-FA/DE, Rev. J, 2011-12-06, Autronica Fire and Security AS...
  • Page 20: Cut Out Dimensions

     Place the cabinet into the wall and fasten the 4 screws. 1.12.6 Reassembling the Mounting Plate  Reassemble the mounting plate carefully into its position inside the cabinet.  Tighten the screws. Installation Handbook, AutroSafe Interactive Fire Alarm System, Release 3, 116-P-ASAFE-FA/DE, Rev. J, 2011-12-06, Autronica Fire and Security AS...
  • Page 21: Cable Inlets / Outlets

    For this purpose, a 19'' mounting plate can be used (UW-1459). Installation Handbook, AutroSafe Interactive Fire Alarm System, Release 3, 116-P-ASAFE-FA/DE, Rev. J, 2011-12-06, Autronica Fire and Security AS...
  • Page 22: Internal Cable Connections

     Remove the fuses F1 and F2 on the Power Supply (refer to illustration in the subsequent chapter). Do not replace the fuses until commissioning of the system. POWER OFF! Installation Handbook, AutroSafe Interactive Fire Alarm System, Release 3, 116-P-ASAFE-FA/DE, Rev. J, 2011-12-06, Autronica Fire and Security AS...
  • Page 23: Location Of Fuses

    T1AL/250V AC Slow (T) External 24V DC Remove fuses F1 and F2. Do not replace the fuses until commissioning of the system. Installation Handbook, AutroSafe Interactive Fire Alarm System, Release 3, 116-P-ASAFE-FA/DE, Rev. J, 2011-12-06, Autronica Fire and Security AS...
  • Page 24: Fuses On Connection Module, Bsf-310B

    4,0 A T4AL/250V AC Slow (T) Battery F2AL/250V AC Fast (F) I/O Power 2,5 A T2,5AL/250V AC Slow (T) Battery / External 24V Installation Handbook, AutroSafe Interactive Fire Alarm System, Release 3, 116-P-ASAFE-FA/DE, Rev. J, 2011-12-06, Autronica Fire and Security AS...
  • Page 25: Shielding And Earthing

    . Schematic outline inside cabinet - Front view Protective Earth (terminal) 230 V AC Power Live Neutral Supply BSS- 103A/02 Installation Handbook, AutroSafe Interactive Fire Alarm System, Release 3, 116-P-ASAFE-FA/DE, Rev. J, 2011-12-06, Autronica Fire and Security AS...
  • Page 26 The isolation of the mains wiring must be of either: inflammability class V2 the wiring has to be fixed to the cabinet separated from all other cables. Installation Handbook, AutroSafe Interactive Fire Alarm System, Release 3, 116-P-ASAFE-FA/DE, Rev. J, 2011-12-06, Autronica Fire and Security AS...
  • Page 27: Connecting The Batteries To Connection Module And Power Supply

    Batteries grease should be applied on the battery poles to 24V/12Ah avoid possible development of verdigris. Connection Module BSF-310B Installation Handbook, AutroSafe Interactive Fire Alarm System, Release 3, 116-P-ASAFE-FA/DE, Rev. J, 2011-12-06, Autronica Fire and Security AS...
  • Page 28 All manuals and user guides at all-guides.com Internal Cable Connections Power Supply 24V / 12Ah Battery Installation Handbook, AutroSafe Interactive Fire Alarm System, Release 3, 116-P-ASAFE-FA/DE, Rev. J, 2011-12-06, Autronica Fire and Security AS...
  • Page 29: Connecting The Network Cables (Autrolon)

    BSF-310B board, and inwards on the EAU-310 board. BSF-310 board EAU-310 4-pin terminal Connector board Connector 4-pin Wires Wires pointing terminal pointing downwards inwards Installation Handbook, AutroSafe Interactive Fire Alarm System, Release 3, 116-P-ASAFE-FA/DE, Rev. J, 2011-12-06, Autronica Fire and Security AS...
  • Page 30: Internal Cable Connections - Overview

    X1-3 To Chassis connection (connection above BSS-103A/02) LON A LON A LON A Installation Handbook, AutroSafe Interactive Fire Alarm System, Release 3, 116-P-ASAFE-FA/DE, Rev. J, 2011-12-06, LON B Autronica Fire and Security AS LON B LON B External 24V +...
  • Page 31 One cable is used to interconnect the Communication Module and the Connection Module BSF-310B. The other cable is used to interconnect the Communication Module and the Power Supply BSS-103A/02. Installation Handbook, AutroSafe Interactive Fire Alarm System, Release 3, 116-P-ASAFE-FA/DE, Rev. J, 2011-12-06, Autronica Fire and Security AS...
  • Page 32: Connections For Temperature Compensated Battery Charging Voltage

    (refer to next chapter). AutroSafe cabinet Fix the temperature sensor to the battery cover bracket with electrical tape. Installation Handbook, AutroSafe Interactive Fire Alarm System, Release 3, 116-P-ASAFE-FA/DE, Rev. J, 2011-12-06, Autronica Fire and Security AS...
  • Page 33: Connecting The Cable To External Temperature Sensor

    Battery Cabinet Fire Alarm Control Panel  Reassemble the front cover on the Power Supply BS-103/01. or Controller Fasten cable with strips Installation Handbook, AutroSafe Interactive Fire Alarm System, Release 3, 116-P-ASAFE-FA/DE, Rev. J, 2011-12-06, Autronica Fire and Security AS...
  • Page 34: Installing I/O Modules

    Note that the internal Power Module (BSS-310) and the Communication Module (BSL-310) are already mounted in a fixed position when the product leaves the factory (refer to 1.5). Installation Handbook, AutroSafe Interactive Fire Alarm System, Release 3, 116-P-ASAFE-FA/DE, Rev. J, 2011-12-06, Autronica Fire and Security AS...
  • Page 35: Front View Of I/O Module

    All manuals and user guides at all-guides.com Installing I/O Modules 3.2 Front View of I/O Module Installation Handbook, AutroSafe Interactive Fire Alarm System, Release 3, 116-P-ASAFE-FA/DE, Rev. J, 2011-12-06, Autronica Fire and Security AS...
  • Page 36: Mounting / Removing I/O Modules

     Then, carefully press the module downwards as far as possible. Make sure that the module is properly connected to the module below. Installation Handbook, AutroSafe Interactive Fire Alarm System, Release 3, 116-P-ASAFE-FA/DE, Rev. J, 2011-12-06, Autronica Fire and Security AS...
  • Page 37: Removing

     Loop Driver Module, BSD-310 / BSD-311  Output Module, monitored, BSB-310  Output Module, BSJ-310  Input Module, monitored, BSE-310  Input Module, BSE-320 Installation Handbook, AutroSafe Interactive Fire Alarm System, Release 3, 116-P-ASAFE-FA/DE, Rev. J, 2011-12-06, Autronica Fire and Security AS...
  • Page 38: Power Module, Bss-310

    H1 (24V) Schematics BSF-310B BSS-310 I/O M odules Chassis 24V DC input Internal + 24V reg Internal BSS-310 + 5V reg Internal Chassis Installation Handbook, AutroSafe Interactive Fire Alarm System, Release 3, 116-P-ASAFE-FA/DE, Rev. J, 2011-12-06, Autronica Fire and Security AS...
  • Page 39: Communication Module, Bsl-310

    To Power Module BSS-103A/02 TEST N.C. N.C. GND MAINS_OK N.C. APPLY_LOAD Schematics BSF-310B Connection Module Cable 1 BSL-310 BSS-103A/02 Power Supply Cable 2 Installation Handbook, AutroSafe Interactive Fire Alarm System, Release 3, 116-P-ASAFE-FA/DE, Rev. J, 2011-12-06, Autronica Fire and Security AS...
  • Page 40: Loop Driver Module, Bsd-310 / Bsd-311

    Schematics BSD-310 Detector 24V DC Out From previous Loop Driver Module Loop Driver F/S Signal Module To next Loop Driver Module Installation Handbook, AutroSafe Interactive Fire Alarm System, Release 3, 116-P-ASAFE-FA/DE, Rev. J, 2011-12-06, Autronica Fire and Security AS...
  • Page 41: Output Module, Monitored, Bsb-310

    Terminal point 1, 3, 5, 7 Schematics - Fault Warning Routing Equipment (FWRE) Output Output 4 only. Ext FW Routing Eq (Not connected) 24V_BAT Sense FWRE 0V_BAT Installation Handbook, AutroSafe Interactive Fire Alarm System, Release 3, 116-P-ASAFE-FA/DE, Rev. J, 2011-12-06, Autronica Fire and Security AS...
  • Page 42: Output Module, Bsj-310

    + Output Terminal 9 +24V External terminal list Output 1 Maximum 100 mA Output 8 Schematics + 24V Output 9 Output 1-8 0V_BAT Installation Handbook, AutroSafe Interactive Fire Alarm System, Release 3, 116-P-ASAFE-FA/DE, Rev. J, 2011-12-06, Autronica Fire and Security AS...
  • Page 43: Input Module, Monitored, Bse-310

    (Recommended value is 470 Ohm) Monitoring resistor Schematics Signal Terminal point 1, 3, 5, 7 Sense Terminal point 2, 4, 6, 8 Installation Handbook, AutroSafe Interactive Fire Alarm System, Release 3, 116-P-ASAFE-FA/DE, Rev. J, 2011-12-06, Autronica Fire and Security AS...
  • Page 44: Input Module, Bse-320

    All manuals and user guides at all-guides.com Installing I/O Modules 3.11 Input Module, BSE-320 Screw Terminal nr. Signal n.c. INx-power supply Common source to all inputs (+) Schematics Installation Handbook, AutroSafe Interactive Fire Alarm System, Release 3, 116-P-ASAFE-FA/DE, Rev. J, 2011-12-06, Autronica Fire and Security AS...
  • Page 45: Larger Distributed Systems

     Maximum 6 Boosters per AUTROLON ring.  Maximum 32 panels per AUTROLON ring.  Maximum length 2,8 km (the total AUTROLON ring with Boosters). Installation Handbook, AutroSafe Interactive Fire Alarm System, Release 3, 116-P-ASAFE-FA/DE, Rev. J, 2011-12-06, Autronica Fire and Security AS...
  • Page 46: Overview - Cable Connections

    All manuals and user guides at all-guides.com 4.3 Overview - Cable Connections Installation Handbook, AutroSafe Interactive Fire Alarm System, Release 3, 116-P-ASAFE-FA/DE, Rev. J, 2011-12-06, Autronica Fire and Security AS...
  • Page 47: Connections To The Autrolon Booster Bsl-325

    LON B (polarity independent) LON B (polarity independent) Shield LON B Do NOT connect Do NOT connect +24 VDC Supply 0 VDC Supply Installation Handbook, AutroSafe Interactive Fire Alarm System, Release 3, 116-P-ASAFE-FA/DE, Rev. J, 2011-12-06, Autronica Fire and Security AS...
  • Page 48: Interfacing Autromaster_5000

    A utro nic a B REAK GLASS B REAK GLASS A utro nica A utro nic a A utro nic a A utro nica Installation Handbook, AutroSafe Interactive Fire Alarm System, Release 3, 116-P-ASAFE-FA/DE, Rev. J, 2011-12-06, Autronica Fire and Security AS...
  • Page 49: Connections - Overview

    RX signals. Testi ng Fire Brig. Disabled Fire Brig. Fau lt System F au lt Alarms Disabled Alarms Fault    Installation Handbook, AutroSafe Interactive Fire Alarm System, Release 3, 116-P-ASAFE-FA/DE, Rev. J, 2011-12-06, Autronica Fire and Security AS...
  • Page 50: Application With Several Autrolon Rings

    (DZ's), which enables alarm transfer to FAI on AUTROLON ring 1. FAI on AUTROLON ring 1 is connected to a Installation Handbook, AutroSafe Interactive Fire Alarm System, Release 3, 116-P-ASAFE-FA/DE, Rev. J, 2011-12-06, Autronica Fire and Security AS...
  • Page 51 Installation Handbook, AutroSafe Interactive Fire Alarm System, Release 3, 116-P-ASAFE-FA/DE, Rev. J, 2011-12-06, Autronica Fire and Security AS...
  • Page 52: Application With Twisted Pair Cabling

    Alarm, Fault Warning 2K End Resistance 2K End Resistance Detection Detection Loop Loop BN-300 BN-310 Note: Make sure that connections are galvanically isolated. Installation Handbook, AutroSafe Interactive Fire Alarm System, Release 3, 116-P-ASAFE-FA/DE, Rev. J, 2011-12-06, Autronica Fire and Security AS...
  • Page 53: Application With Fibre Optic Cabling

    Early Warning Fault Fault System Fault System Fault Function Disabled Function Disabled Test Test Self Verify Self Verify Converter Converter Converter Converter Installation Handbook, AutroSafe Interactive Fire Alarm System, Release 3, 116-P-ASAFE-FA/DE, Rev. J, 2011-12-06, Autronica Fire and Security AS...
  • Page 54: Guidelines For The Installation And Addressing Of Loop Units

    K NU S GL A S SET P R ES S H E R E B R E A K GL A S S FARE Installation Handbook, AutroSafe Interactive Fire Alarm System, Release 3, 116-P-ASAFE-FA/DE, Rev. J, 2011-12-06, Autronica Fire and Security AS...
  • Page 55: Which Parameters Are Known

    For verification only: remove parameters. and paste the sticker with the Production Number in its correct position on the list, beside the corresponding Tag Name. Installation Handbook, AutroSafe Interactive Fire Alarm System, Release 3, 116-P-ASAFE-FA/DE, Rev. J, 2011-12-06, Autronica Fire and Security AS...
  • Page 56: Guidelines - Unknown Cable Layout

    AutroSafe Configuration Numbers are entered Tool beside its corresponding Tag into the Configuration Name. Tool, the system will know all three parameters. Installation Handbook, AutroSafe Interactive Fire Alarm System, Release 3, 116-P-ASAFE-FA/DE, Rev. J, 2011-12-06, Autronica Fire and Security AS...
  • Page 57: Service And Maintenance

    For SIL2 approved systems, service and maintenance shall be carried out according to the proof test interval in chapter 4; Reliability Accessments in RAMS report 2053 Rev A. Installation Handbook, AutroSafe Interactive Fire Alarm System, Release 3, 116-P-ASAFE-FA/DE, Rev. J, 2011-12-06, Autronica Fire and Security AS...
  • Page 58 Complete a service report and service log. The battery should be changed every 4 years. If a fault arises on the panel that cannot be rectified, contact your nearest Autronica Fire and Security office for qualified assistance. Installation Handbook, AutroSafe Interactive Fire Alarm System, Release 3, 116-P-ASAFE-FA/DE, Rev.
  • Page 59 All manuals and user guides at all-guides.com Service and Maintenance Installation Handbook, AutroSafe Interactive Fire Alarm System, Release 3, 116-P-ASAFE-FA/DE, Rev. J, 2011-12-06, Autronica Fire and Security AS...
  • Page 60 All manuals and user guides at all-guides.com...
  • Page 61 AutroSafe Interactive Fire Alarm System, Release 3, Ref. No.: 116-P-ASAFE-FA/DE, Rev. J, 2011-12-06 Your information on any inaccuracies or omissions (with page reference): Please turn the page Installation Handbook, AutroSafe Interactive Fire Alarm System, Release 3, 116-P-ASAFE-FA/DE, Rev. J, 2011-12-06, Autronica Fire and Security AS...
  • Page 62 ------------------------------------------------------------------------------------------------ Fax: ------------------------------------------------------------------------------------------------ Date: ------------------------------------------------------------------------------------------------ Please send this form to: Autronica Fire and Security AS N-7483 Trondheim Norway Tel: + 47 73 58 25 00 Fax: + 47 73 58 25 01 www.autronicafire.com/ Installation Handbook, AutroSafe Interactive Fire Alarm System, Release 3, 116-P-ASAFE-FA/DE, Rev. J, 2011-12-06,...
  • Page 63 All manuals and user guides at all-guides.com Reader’s Comments Installation Handbook, AutroSafe Interactive Fire Alarm System, Release 3, 116-P-ASAFE-FA/DE, Rev. J, 2011-12-06, Autronica Fire and Security AS...
  • Page 64 Oil & Gas, Stavanger, Norway. Phone: + 47 51 84 09 00, fax: + 47 51 84 09 99. Autronica Industrial Ltd., Watford, United Kingdom. Phone: 1923 23 37 68, fax: 1923 22 55 77. Visit Autronica Fire and Security's Web site:...

Table of Contents